美国vanguard CT-7000 S3数字断路器分析仪
美国vanguard CT-7000 S3数字断路器分析仪
产品价格:(人民币)
  • 规格:CT-7000 S3
  • 发货地:上海
  • 品牌:
  • 最小起订量:1件
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:上海山合海融商贸有限公司

    联系人:孙宝金(先生)

    联系手机:

    固定电话:

    企业邮箱:sh@51082245.com

    联系地址:上海市宝山区陆翔路678弄60号

    邮编:201907

    联系我时,请说是在智能安防网上看到的,谢谢!

    商品详情

      The CT-7000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-7000 S3 is available with 3 (part number 9021-UC) or 6 contact timing channels (part number 9100-UC). The CT-7000 S3 can fully analyze a circuit breaker's performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Both contact and motion analysis can be performed on all circuit breaker operations (OPEN, CLOSE, OPEN-CLOSE, CLOSE-OPEN, and OPEN CLOSE-OPEN). The CT-7000 S3's timing window is selectable between 1 second, 10 seconds, and 20 seconds.


      • Fully analyze circuit breaker's performance by measuring main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes
      • USB computer interface
      • USB Flash drive interface (Flash drive not included)
      • Store up to 200 test records and 100 test plans internally
      • Initiate Breaker Operation
      • Built-in 4.5" wide Thermal Printer
      • Rugged "QWERTY" style membrane keypad
      • Optional "On-line" Timing Mode
      • Optional dual ground testing mode
      • Optional Bluetooth wireless computer interface

      CT-7000 S3

      Cables

       
             
             

      CT-7000 S3

      Technical Specifications

       
             
      TYPE Portable circuit-breaker analyzer
      PHYSICAL SPECIFICATIONS Dimensions: 21.5”W x 8”H x 14” D (53 cm x 20 cm x 35 cm)
      Weight: 15 lbs (6.8 Kg)
      INPUT POWER 100-240Vac, 3A, 50/60Hz
      DRY-CONTACT INPUTS 3 channels (9021-UC) or 6 channels (9100-UC). Channel can detect the main contact and resistor contact time.
      TIMING WINDOWS 1 second, 10 seconds, or 20 seconds
      TIMING RESOLUTIONS ±50 micro-seconds @ 1 sec. duration,
      ±500 micro-seconds @ 10 sec. duration,
      ±1.0 milli-seconds @ 20 sec. duration
      TIMING ACCURACY 0.05% of reading ±0.05 ms @ 1 second duration
      DRY-CONTACT CHANNEL PROTECTION All contact inputs are grounded until test. Input channels are also protected against static discharge.
      DRY-CONTACT DETECTION RANGE Closed: Less than 20 Ohm. Opened: greater than 5000 ohm
      INSERTION RESISTOR DETECTION RANGE 50 – 5,000 ohms
      TRIGGER INPUT VOLTAGE Open/Close trigger voltage: 24 V – 300V DC or peak AC
      VOLTAGE SENSING INPUT RANGE V1: analog input; 0 – 250 V DC or peak AC; sensitivity ±1 V; record and print voltage level
      V2 and V3: voltage presence/absence detector input; 24 – 255 V DC or peak AC; record and print 3 timing events
      BREAKER OPERATIONS Initiate Open, Close, Open-Close, Close-Open, Open-Close-Open
      BREAKER INITIATE CAPACITY 30A, 250 Vac/dc max
      INITIATE CURRENT READING RANGE one, non-contact, Hall-effect sensor, 0 – 20 amp range, dc to 5 Khz AC
      DIGITAL TRAVEL TRANSDUCER INPUTS 3 channels, 200 ohm – 10K ohms
      CONTACT TRAVEL POINT DIFFERENCE measures “slow-close” contact-point distances; results can be printed
      DISPLAY back-lit LCD screen (128 x 240 pixels); viewable in bright sunlight and low light
      PRINTER built-in 4.5” wide thermal printer that can print both graphic contact travel waveforms and tabulated test results
      INTERNAL TEST RECORD STORAGE Store up to 200 test records and 100 test plans
      EXTERNAL TEST RECORD STORAGE USB Flash drive interface for external storage of test records and test plans
      COMPUTER INTERFACES One USB port, optional Bluetooth wireless interface
      PC SOFTWARE Windows? based Breaker Analysis software included with purchase price
      CABLES furnished with full set of test leads
      OPTIONS transportation cases (available for the CT-7000 S3 and travel transducers), on-line timing mode, dual ground testing mode,
      bluetooth interface
      SAFETY designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92 standards
      ENVIRONMENT Operating: -10°C to +50°C (+15°F to +122°F); Storage: -30°C to +70°C (-22°F to +158°F)
      HUMIDITY 90% RH @ 40°C (104°F) non-condensing
      ALTITUDE 2,000 m (6,562 ft) to full safety specifi cations
      WARRANTY one year on parts and labor
      Specifications are valid at nominal voltage and ambient temperature of +25?C (+77?F).



    在线询盘/留言
  • 0571-87774297