      PFCL ELITE ADVANCED CONTROLLER
      Description
      PFCL Elite controller has a built in power analyzer allowing the measurement of main electrical parameters (voltage, current, harmonics, active and reactive power, apparent power, etc.). The device gives a detailed information on both, voltage and current harmonic components. PFCL Elite controller measures also ambient temperature and keeps a record of maximum and minimum values of all measured parameters.

      - Serial Communications
      - AUTO-ON-OFF Function
      - Plug and Play
      - Built-in leakage control
      - Safety and maintenance

      PFCL Elite performs a capacitor test every time that a capacitor step is switched ON. The real power and the leakage current of each step can be displayed.
      Up to 14 different alarm conditions can be programmed.
      Internal counter register which counts the number of operations of each individual capacitor step
      ALSO AVAILABLE FAST VERSION FOR STATIC CONTACTORS WITH THYRISTORS


      Part number

      Model

      Power (V)

      Size (mm)

      Steps

      Price(€)

      PFCL06230

      PFCL Elite 6

      230

      144x144

      6

      300

      PFCL06400

      PFCL Elite 6

      400

      144x144

      6

      275

      PFCL12230

      PFCL Elite 12

      230

      144x144

      12

      350

      PFCL12400

      PFCL Elite 12

      400

      144x144

      12

      325

      PFCL06110

      PFCL Elite 6

      110

      144x144

      6

      300

      Reactive power controllers PFCL Elite 
      PFCL06230 PFCL Elite 6 PFCL06400 PFCL Elite 6 PFCL12230 PFCL Elite 12 PFCL12400 PFCL Elite 12 PFCL06110 PFCL Elite 6

      Reactive Power Controllers
      Description
      Reactive power controllers MCE ADV, PFCL and MASTER are designed to measure the reactive power of an installation and to give the necessary instructions for connecting and disconnecting capacitors in order to maintain the desired cos ¦Õ . 
      All the controllers are commanded by a microprocessor that ensures an uniform ageing of contactors and capacitors by using a circular connection sequence that takes into account the time that each capacitor has been switched on. 
      Power factor value to be reached can be adjusted in a continuous way, between 0.85 inductive and 0.95 capacitive.
      Standard working programs for controllers are 1:1:1:1, 
      1:2:2:2, 1:2:4:4, 1:2:4:8 and 1:1:2:2.
      Advantages 
      Uniform ageing of the capacitors and contactors
      High speed operation with less number of switchings
      True rms measuring circuit, insensitive to harmonics
      Automatic disconnection of all the capacitors in the case of 
      a failure in the electrical network
      Detection and automatic indication of current transformer 
      wrongly connected 
      Digital cos ¦Õ display
      Adjustable operation delay
      Power factor alarm relay (PFCL/MASTER)
      Harmonic distortion alarm relay (PFCL/MASTER)
      Some others advanced features, depending on the model.
      Range
      MCE ADV, of 6 or 12 steps, for standard automatic bank.
      PFCL, available with 6 and 12 relays, size 144x144mm with special alarms and communication.
      MASTER, available with 6, 12 and 14 relays, size 144x144mm with special alarms and communication.


      Î÷°àÑÀLIFASA¹«Ë¾×Ô1949ÄêÆðÉú²ú¸ßÆ·ÖʵçÈݵȲúÆ·£¬Ôڸ߼¶¾ÆµêºÍ´óÏÃÓõçÈÝÁìÓòÕ¼¾Ý¾ø¶ÔÓÅÊÆ£¬³¬¹ý50%µÄ²úÆ·³ö¿Úµ½ÆäËûÊÀ½ç¸÷µØ£¬²úÆ·³©ÏúÎå´óÖÞÆßÊ®¶à¸ö¹ú¼Ò¡£²úÆ·ÖÊÁ¿·ûºÏISO 9000±ê×¼¡£²úÆ·°üÀ¨£ºÂí´ïÆô¶¯µçÈÝ¡¢¸ßѹµçÁ¦µçÈÝÆ÷¡¢ÕÕÃ÷µçÈÝÆ÷¡¢µçÈÝÆ÷×é¡¢¸½½Ó´¥Æ÷ÎÞ¹¦²¹³¥µçÈÝ¡¢Â˲¨×迹µçÈÝ¡¢ÂÁµç½âµçÈÝÆ÷¡¢¸ßƵÅÔ·µçÈÝÆ÷¡¢¸ßƵñîºÏµçÈÝÆ÷¡¢ÌմɵçÈÝÆ÷¡¢µ÷гµçÈÝÆ÷¡¢¾Û±½ÒÒÏ©µçÈÝÆ÷¡¢ËÜÁϱ¡Ä¤µçÈÝÆ÷¡¢ÎüÊÕ¹ýÂËÆ÷¡­
          Î÷°àÑÀLIFASA²úÆ··ûºÏ¹ú¼Êµç¹¤Î¯Ô±»áÍƼö±ê×¼IEC831-1¼°IEC831-2¡¶¶î¶¨µçѹ660V¼°ÒÔϽ»Á÷ϵͳÓÃ×ÔÓúʽ²¢ÁªµçÁ¦µçÈÝÆ÷¡·¡£ LIFASAµçÈÝÆ÷ϵÊÊÓÃÓÚ¹¤Æµ50Hz»ò60Hz¡¢¶î¶¨µçѹ1000V¼°ÒÔϵĽ»Á÷µçÁ¦ÏµÍ³ÖÐÓ븺Ôز¢Áª£¬ÒÔÌá¸ßϵͳµÄ¹¦ÂÊÒòÊý¡£¸ÃµçÈÝÆ÷ÒÔ½ðÊô»¯¾Û±ûÏ©±¡Ä¤×÷µç¼«ºÍ½éÖÊ£¬Òò¶ø²úÆ·¾ßÓÐ×ÔÓúÐÔÄÜ£¬²¢Í¬Ê±¾ßÓÐÖØÁ¿Çá¡¢Ìå»ýС¡¢ËðºÄµÍµÈÓŵ㡣¶øÇÒµçÈÝÆ÷ÄÚ²¿×°ÓйýѹÁ¦±£»¤×°ÖᢹýµçÁ÷±£»¤Æ÷ºÍ·Åµçµç×裬ÓкܸߵĿɿ¿ÐԺͰ²È«ÐÔ¡£ Î÷°àÑÀLIFASAµçÈÝÆ÷²ÉÓöÀÌØÉè¼ÆµÄ×ÔÓúʽ½ðÊô»¯±¡Ä¤£¬´ó´óÔöÇ¿Á˵çÈÝÆ÷Ôª¼þµÄ¶ËÃæ½ÓºÏÁ¦ºÍ¸ßÄÍѹµÄÒªÇ󣬴ӶøÌá¸ßÁ˵çÈÝÆ÷µÄ¿¹Ó¿Á÷ÐÔÄܺͿɿ¿ÐÔ£»¼õÉÙÁËͶÈëµçÈÝÆ÷˲¼ä¶ÔÔª¼þµÄµçÁ÷³å»÷£¬´Ó¶øÓÐЧÑÓ³¤µçÈÝÆ÷µÄʹÓÃÊÙÃü¡£

      ²úÆ·Ìص㣺
      1£® ÂÝ˨³öÏß·½Ê½£¬±£Ö¤Á˽ÓÏߵĿɿ¿Îȶ¨£¬Âú×ã´óÈÝÁ¿¡¢´óµçÁ÷µÄÒªÇó£» 
      2£® °²È«¿É¿¿µÄÃÀʽ¹ýѹÁ¦·À±¬½á¹¹£¬ÄÚÖÃʽ·Åµçµç×裬ʹµÃ²úÆ·¸ü°²È«£¬¸ü¿É¿¿£» 
      3£® ³¤ÊÙÃü¡¢¶àÔª¼þÉè¼Æ£¬Ôö¼ÓÉ¢ÈÈÃæ»ý£¬Ê¹µçÈÝÆ÷µÄÎÂÉý¸üµÍ£¬ÑÓ³¤µçÈÝÆ÷µÄʹÓÃÊÙÃü£¬Æ½¾ùÊÙÃü´ïµ½100,000Сʱ£» 
      4£® µçÈÝÆ÷Ôª¼þÓýðÊô»¯±¡Ä¤²ÉÓÃÌرðµÄ·½×èÉè¼Æ£¬¼ÈÓкܸߵÄ×ÔÓúÐÔÄÜ£¬ÓÖÂú×ãÁ˸߿ɿ¿ÐԵĽӴ¥ºÍ¸ßÄÍѹµÄÒªÇó£» 
      5£® °²È«ÓÐЧµÄ·À»¤´ëÊ©£¬Ãâ³ý¶ÔÈËÌåµÄÉ˺¦£» 
      6£® ·½±ã¿É¿¿µÄ°²×°·½Ê½£¬Ìá¸ßÁ˹¤×÷ЧÂÊ£» 
      7£® ÓÅÖÊÔ²ÖùÐÎÂÁÍâ¿Ç£¬ÃÀ¹ÛƯÁÁ£¬¸üСµÄÌå»ý£¬Ê¹µÃµ¥¹ñµÄÈÝÁ¿¸ü´ó¡£¹¤Òµ²úÆ·µÄÉè¼Æ¼Òµç»¯£¬ÌáÉý³ÉÆ·ÐÎÏó£¬Îª¿Í»§´´Ôì×î´ó¼ÛÖµ¡£ 
      8£® ²úÆ··ûºÏIEC831-1£¬IEC831-2¹ú¼Ê±ê×¼ºÍGB/T12747-2004¹ú¼Ò±ê×¼µÄÒªÇó¡£

      ¹«Ë¾½éÉÜ£º
      More than 60 years of history
      International Capacitors S.A. is a consolidated company in both Spanish and international markets thanks to many years of experience and dedication to what it has been its product par excellence along its history: the capacitor for the electrical installation. With its commercial brand name LIFASA, present in the market for more than 60 years and a constant technical and technological evolution, it has succeeded in getting adapted continuously to the progress and market requirements nowadays.
      LIFASA capacitors are present in the market since 1949. More than 50 % are exported to 70 countries in five continents. Capacitors are manufactured according to European and other International Standards. They have obtained large number of certificates and approvals.
      60¶àÄêµÄ¹«Ë¾ÀúÊ·
      International Capacitors S.A.£¨Î÷°àÑÀ¹ú¼ÊµçÈÝÆ÷¹«Ë¾£©×÷Ϊһ¼Ò×ÛºÏÐ͹«Ë¾£¬µÃÒæÓÚ¶àÄêµÄ¾­ÑéºÍ·îÏ×¾«Éñ£¬Æ¾½è׏«Ë¾·¢Õ¹ÀúÊ·ÖÐÒýÒÔΪºÀµÄµçÆø°²×°ÏµÍ³ÖеĵçÈÝÆ÷²úÆ·£¬ÎªÎ÷°àÑÀ¹úÄں͹ú¼ÊÊг¡ÌṩÁË´óÁ¿×¿Ô½µÄµçÈÝÆ÷²úÆ·¡£½èÖú³¬¹ý60ÄêÀúÊ·µÄÉÌҵƷÅÆLIFASAºÍ³ÖÐøµÄ¿Æ¼¼·¢Õ¹£¬ÏÖÔÚËüÒѾ­³É¹¦µØµÃµ½³ÖÐøµÄÔö³¤ºÍÊÊÓ¦Êг¡µÄÐèÇó¡£
      LIFASAµçÈÝÆ÷×Ô1949ÃæÊÐÒÔÀ´£¬³¬¹ý50%µÄ²úÆ·³ö¿Úµ½Îå´óÖÞµÄ70¸ö¹ú¼Ò¡£µçÈÝÆ÷ÊǸù¾ÝÅ·ÖÞºÍÆäËû¹ú¼Ê±ê×¼ÖÆÔìµÄ£¬»ñµÃÁË´óÁ¿µÄÖ¤ÊéºÍÅú×¼Îļþ¡£
      Highest quality standards
      International Capacitors S.A. has been from its beginnings a pioneering company in the promotion of the quality of its products. Since 1987, it maintains an ISO9000 Quality System periodically audited by international bodies.
      At present, it has quintuple certification ISO9001:2008, ISO14001:2004, OSHAS 18001:2007, IEC QC 080000-RoHS and REACH, that guarantees the highest quality standards in its products, while they are manufactured in a way both environmentally friendly and safe and healthy for its workers. It also has energy efficiency certification ISO 50001:2011
      All products included in this catalogue fully comply with the requirements of RoHS Directive.
      ×î¸ßµÄÖÊÁ¿±ê×¼ 
      International Capacitors S.A.£¨Î÷°àÑÀ¹ú¼ÊµçÈÝÆ÷¹«Ë¾£©ÔçÒѲ»ÊÇÒ»¸öÒÀÀµÌáÉýÆä²úÆ·ÖÊÁ¿µÄ³õ´´¹«Ë¾¡£×Ô1987ÄêÒÔÀ´£¬Ò»Ö±»ñµÃ¹ú¼Ê×éÖ¯ÈϿɵÄISO9000ÖÊÁ¿ÌåϵÈÏÖ¤¡£
      Ä¿Ç°£¬¹«Ë¾ÓµÓÐÎåÏîȨÍþÈÏÖ¤£ºISO9001:2008¡¢ISO14001:2004¡¢OSHAS 18001:2007£¬IEC QC 080000 RoHSºÍREACH£¬ÒÔÈ·±£²úÆ·µÄ×î¸ßÖÊÁ¿±ê×¼¡£Óë´ËͬʱËûÃÇΪÉú²úÕßÓªÔìÒ»¸ö¼È»·±£ÓÖ°²È«½¡¿µµÄ¹¤×÷»·¾³¡£Ëü»¹¾ßÓнÚÄÜÈÏÖ¤ 50001:2011¡£
      ±¾ÊÖ²áÖеÄËùÓвúÆ·¶¼ÍêÈ«·ûºÏRoHSÖ¸ÁîµÄÒªÇó¡£
      Comprehensive services
      The company is commited to give the best service with maximum flexibility to meet customer requirements.
      Economical and technical advices.
      Support in installation and commissioning.
      Permanent support during the whole life of our products.
      Trainig on site and in factory.
      International warranty.
      Every person in the company is trained and motivated to participate actively in achieving this objective.
      È«·½Î»µÄ·þÎñ
      ¹«Ë¾ÖÂÁ¦ÓÚÒÔ×î´óµÄÁé»îÐÔÌṩ×îºÃµÄ·þÎñ£¬ÒÔÂú×ã¿Í»§µÄÒªÇó¡£
      ¾­¼ÃºÍ¼¼Êõ½¨Òé¡£ 
      ÔÚ°²×°ºÍµ÷ÊÔ¹ý³ÌÖÐÌṩ֧³Ö¡£ 
      ÔÚÎÒÃDzúÆ·µÄÕû¸öÉúÃü¹ý³ÌÖÐÓÀ¾ÃÐÔµÄÖ§³Ö¡£ 
      ÏÖ³¡ºÍ¹¤³§Åàѵ¡£ 
      ¹ú¼Ê·¶Î§Äڵı£ÐÞ¡£
      ¹«Ë¾ÖеÄÿһλԱ¹¤¶¼»ñµÃÁ¼ºÃµÄÅàѵ²¢»ý¼«²ÎÓëÒÔʵÏÖÕâһĿ±ê¡£

      ÉϺ£É½ºÏº£ÈÚÉÌóÓÐÏÞ¹«Ë¾ÌṩÒÔÏÂÎ÷°àÑÀLIFASAÆ·ÅƵIJúÆ·£¬ÈçÓÐÐèÒª£¬»¶Ó­ÓëÎÒÃÇÁªÏµ¡£

      µçÁ¦µçÈÝÆ÷Power capacitors
      ELEFPµ¥ÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
      POLTÈýÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
      POLBÈýÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
      FMLIµ¥ÏàÂÁµç½âµçÈÝÆ÷Pricsmatic capacitor
      FML±ê×¼ÐÍÂÁµç½âµçÈÝÆ÷Standard capacitor
      FML(R460)¼ÓÇ¿ÐÍÂÁµç½âµçÈÝÆ÷Reinforced capacitor
      MFBÈýÏà½ô´ÕÐ͵çÈÝÆ÷Compact prismatic capacitor
      FMLSÁùÏßµçÈÝÆ÷6-terminals prismatic capacitor
      CPF´øÈÛ¶ÏÆ÷µÄµçÈÝÆ÷Capacitor with fuses
      CPM´ø¶Ï·Æ÷µÄµçÈÝÆ÷Capacitor with breaker
      CAB´øÈÛ¶ÏÆ÷ºÍ½Ó´¥Æ÷µçÈÝÆ÷Capacitor with fuse and contactor

      г²¨Â˲¨Æ÷Harmonic filters
      HBF-TµÚÈýг²¨Â˲¨Æ÷Third harmonic filter
      TFAµÚÈýг²¨¸ôÀëÂ˲¨Æ÷Third harmonic isolation
      HAFÎüÊÕÂ˹âÆ÷Absorption filter
      HPF¸ßͨÂ˲¨Æ÷High pass filter
      SINAF 2.0ÓÐÔ´Â˲¨Æ÷Active filter

      ÐÂÐ͵çÈÝÆ÷ʽ½Ó´¥Æ÷KMLϵÁÐContactor for Capacitors
      µçÈÝÆ÷¹ñAutomatic Banks
      BATM080 Automatic Banks
      BATLV180 Automatic Banks
      BATLV360 Automatic Banks
      BATLV400 Automatic Banks
      BATLV480 Automatic Banks
      BATLV800 Automatic Banks
      BATLV1200 Automatic Banks
      BATLV1600 Automatic Banks
      BATLVF080´ø±ê×¼µçÈÝÆ÷
      BATLVF400´ø±ê×¼µçÈÝÆ÷
      BATLVF600´ø±ê×¼µçÈÝÆ÷
      BATLVF800´ø±ê×¼µçÈÝÆ÷
      BATLVF1000´ø±ê×¼µçÈÝÆ÷
      BATLVF1200´ø±ê×¼µçÈÝÆ÷
      BATLVFS400´ø¾§Õ¢¹ÜThyristors
      BATLVFS600´ø¾§Õ¢¹ÜThyristors
      BATLVFS800´ø¾§Õ¢¹ÜThyristors
      BATLVFS1000´ø¾§Õ¢¹ÜThyristors
      BATLVFS1200´ø¾§Õ¢¹ÜThyristors


      ·À»¤Â˲¨Æ÷Protection filters
      INA/INR±ê×¼µçÈÝÆ÷¹ñµç¿¹Æ÷£¨Reactor for standard capacitor bank£©
      INAS/INRS¾²Ì¬µçÈÝÆ÷¹ñµç¿¹Æ÷£¨Reactor for static bank£©
      FMLFг²¨±£»¤µçÈÝÆ÷Capacitor for harmonic protection
      FMLS¾²Ì¬Â˲¨µçÈÝÆ÷Capacitor for static filter
      ÎÞ¹¦¹¦ÂÊ¿ØÖÆÆ÷Reactive power controllers
      MCE ADV±ê×¼¿ØÖÆÆ÷Standard controller
      MCE-F PLUS¾²Ì¬¹ñ¿ØÖÆÆ÷£¨Controller static bank£©
      PFCL ELITE¸ß¼¶¿ØÖÆÆ÷ADVANCED CONTROLLER
      ¸½¼þAccessories and auxiliary
      ·Åµçµç×è¡¢±äѹÆ÷¡¢¼ÌµçÆ÷
      TCPµçÁ÷»¥¸ÐÆ÷Current transformer with split-core
      MCµçÈݽӴ¥Æ÷Contator for capacitor
      CTF-CTB¾²Ì¬¿ª¹ØÄ£¿éStatic switching module
      MCA PLUSÍøÂç·ÖÎöÒÇNetwork analyser
      MOD-RACK´ø±ê×¼µçÈÝÆ÷µÄ°²×°¼ÜRack-mounting
      µç»úºÍÕÕÃ÷µçÈÝÆ÷MOTOR AND LIGHTING CAPACITORS
      µç»úÔËÐеçÈÝÆ÷MOTOR RUN CAPACITORS
      ÕÕÃ÷ÓõçÈÝÆ÷LIGHTING CAPACITORS

    ÔÚÏßѯÅÌ/ÁôÑÔ