HBF-T THIRD HARMONIC FILTER
Description
Filters HBF-T are designed for the blockade of 3rd harmonic, reducing the
currents of neutral in three-phase installation where there is installed con-
nected between neutral phase. It is basically passive filters with a parallel
combination of inductance and condenser, being his advantages of use the
following ones:
Reduction of the third overtone until a 90%.
Significant Reduction of other overtones
Reduction current of neutral absorbed
Reduction of losses in the installation
Reduction of the interferences
Improvement of the power factor
Technical Characteristics
Tensi¨®n Fase-Neutro/Phase-neutral tension ..................... Hasta/Up to 750 V
Frecuencia/Frequency .......................................................... 50 / 60Hz
Corriente nominal (IR)/Nominal current (IR) ..................... 6 ... 100 A
Corriente max. transitoria/Current max. transitory ....... 1,5 In (1min. de cada 10 minutos)/(1 min. of each 10 min.)
Grado de protecci¨®n/Degree of protection ................... IP 00/IP21
Color/Colour .......................................................................... Gris/Grey RAL 7035
Instalaci¨®n/Installation ......................................................... Interior/Indoor
Gama climatica/Temperature range ................................ -10o a +50oC
Protecci¨®n/Protection ........................................................... IP21
Current | Dimensions | Price(€) |
6A | 300x200x200 | 926 |
10A | 300x200x200 | 1.048 |
16A | 300x200x200 | 1.086 |
25A | 370x280x300 | 1.304 |
32A | 370x280x300 | 1.368 |
50A | 370x280x300 | 1.439 |
63A | 370x420x370 | 1.814 |
100A | 370x420x370 | 2.029 |
|
Harmonic Filters
These filters are used when the main objective is not the reactive power compensation at the fundamental frequency, but to reduce the harmonic distortion in the supply system.
Among the problems caused by harmonics and which may make their suppression necessary, are the following:
Interferences in telecommunications.
Distortion on the mains voltage.
Disturbances in electronic systems.
Erratic operation of control and protection relays .
Failures in transformers and motors, due to overheating caused by losses on the core.
Overheating of protective fuses to the point where a minor spike on the line causes them to blow.
It should be pointed out that the impedance of all the filters is capacitive below its tuning frequency, whereby they also contribute, even if in a small scale, to the reactive power compensation at the fundamental frequency.
Installation of filters produces a modification on the topology of the electrical supply system. For this reason, the design of filters must be done with regard to an accurate analysis and study of the whole system.
According to the application, there are different types of filters:
3rd harmonic filter HBF-T
Isolation filter
Absortion filter HAF
High pass filter HPF
Active filter SINAF 2.0
|
Î÷°àÑÀLIFASA¹«Ë¾×Ô1949ÄêÆðÉú²ú¸ßÆ·ÖʵçÈݵȲúÆ·£¬Ôڸ߼¶¾ÆµêºÍ´óÏÃÓõçÈÝÁìÓòÕ¼¾Ý¾ø¶ÔÓÅÊÆ£¬³¬¹ý50%µÄ²úÆ·³ö¿Úµ½ÆäËûÊÀ½ç¸÷µØ£¬²úÆ·³©ÏúÎå´óÖÞÆßÊ®¶à¸ö¹ú¼Ò¡£²úÆ·ÖÊÁ¿·ûºÏISO 9000±ê×¼¡£²úÆ·°üÀ¨£ºÂí´ïÆô¶¯µçÈÝ¡¢¸ßѹµçÁ¦µçÈÝÆ÷¡¢ÕÕÃ÷µçÈÝÆ÷¡¢µçÈÝÆ÷×é¡¢¸½½Ó´¥Æ÷ÎÞ¹¦²¹³¥µçÈÝ¡¢Â˲¨×迹µçÈÝ¡¢ÂÁµç½âµçÈÝÆ÷¡¢¸ßƵÅÔ·µçÈÝÆ÷¡¢¸ßƵñîºÏµçÈÝÆ÷¡¢ÌմɵçÈÝÆ÷¡¢µ÷гµçÈÝÆ÷¡¢¾Û±½ÒÒÏ©µçÈÝÆ÷¡¢ËÜÁϱ¡Ä¤µçÈÝÆ÷¡¢ÎüÊÕ¹ýÂËÆ÷¡
Î÷°àÑÀLIFASA²úÆ··ûºÏ¹ú¼Êµç¹¤Î¯Ô±»áÍƼö±ê×¼IEC831-1¼°IEC831-2¡¶¶î¶¨µçѹ660V¼°ÒÔϽ»Á÷ϵͳÓÃ×ÔÓúʽ²¢ÁªµçÁ¦µçÈÝÆ÷¡·¡£ LIFASAµçÈÝÆ÷ϵÊÊÓÃÓÚ¹¤Æµ50Hz»ò60Hz¡¢¶î¶¨µçѹ1000V¼°ÒÔϵĽ»Á÷µçÁ¦ÏµÍ³ÖÐÓ븺Ôز¢Áª£¬ÒÔÌá¸ßϵͳµÄ¹¦ÂÊÒòÊý¡£¸ÃµçÈÝÆ÷ÒÔ½ðÊô»¯¾Û±ûÏ©±¡Ä¤×÷µç¼«ºÍ½éÖÊ£¬Òò¶ø²úÆ·¾ßÓÐ×ÔÓúÐÔÄÜ£¬²¢Í¬Ê±¾ßÓÐÖØÁ¿Çá¡¢Ìå»ýС¡¢ËðºÄµÍµÈÓŵ㡣¶øÇÒµçÈÝÆ÷ÄÚ²¿×°ÓйýѹÁ¦±£»¤×°ÖᢹýµçÁ÷±£»¤Æ÷ºÍ·Åµçµç×裬ÓкܸߵĿɿ¿ÐԺͰ²È«ÐÔ¡£ Î÷°àÑÀLIFASAµçÈÝÆ÷²ÉÓöÀÌØÉè¼ÆµÄ×ÔÓúʽ½ðÊô»¯±¡Ä¤£¬´ó´óÔöÇ¿Á˵çÈÝÆ÷Ôª¼þµÄ¶ËÃæ½ÓºÏÁ¦ºÍ¸ßÄÍѹµÄÒªÇ󣬴ӶøÌá¸ßÁ˵çÈÝÆ÷µÄ¿¹Ó¿Á÷ÐÔÄܺͿɿ¿ÐÔ£»¼õÉÙÁËͶÈëµçÈÝÆ÷˲¼ä¶ÔÔª¼þµÄµçÁ÷³å»÷£¬´Ó¶øÓÐЧÑÓ³¤µçÈÝÆ÷µÄʹÓÃÊÙÃü¡£
²úÆ·Ìص㣺
1£® ÂÝ˨³öÏß·½Ê½£¬±£Ö¤Á˽ÓÏߵĿɿ¿Îȶ¨£¬Âú×ã´óÈÝÁ¿¡¢´óµçÁ÷µÄÒªÇó£»
2£® °²È«¿É¿¿µÄÃÀʽ¹ýѹÁ¦·À±¬½á¹¹£¬ÄÚÖÃʽ·Åµçµç×裬ʹµÃ²úÆ·¸ü°²È«£¬¸ü¿É¿¿£»
3£® ³¤ÊÙÃü¡¢¶àÔª¼þÉè¼Æ£¬Ôö¼ÓÉ¢ÈÈÃæ»ý£¬Ê¹µçÈÝÆ÷µÄÎÂÉý¸üµÍ£¬ÑÓ³¤µçÈÝÆ÷µÄʹÓÃÊÙÃü£¬Æ½¾ùÊÙÃü´ïµ½100,000Сʱ£»
4£® µçÈÝÆ÷Ôª¼þÓýðÊô»¯±¡Ä¤²ÉÓÃÌرðµÄ·½×èÉè¼Æ£¬¼ÈÓкܸߵÄ×ÔÓúÐÔÄÜ£¬ÓÖÂú×ãÁ˸߿ɿ¿ÐԵĽӴ¥ºÍ¸ßÄÍѹµÄÒªÇó£»
5£® °²È«ÓÐЧµÄ·À»¤´ëÊ©£¬Ãâ³ý¶ÔÈËÌåµÄÉ˺¦£»
6£® ·½±ã¿É¿¿µÄ°²×°·½Ê½£¬Ìá¸ßÁ˹¤×÷ЧÂÊ£»
7£® ÓÅÖÊÔ²ÖùÐÎÂÁÍâ¿Ç£¬ÃÀ¹ÛƯÁÁ£¬¸üСµÄÌå»ý£¬Ê¹µÃµ¥¹ñµÄÈÝÁ¿¸ü´ó¡£¹¤Òµ²úÆ·µÄÉè¼Æ¼Òµç»¯£¬ÌáÉý³ÉÆ·ÐÎÏó£¬Îª¿Í»§´´Ôì×î´ó¼ÛÖµ¡£
8£® ²úÆ··ûºÏIEC831-1£¬IEC831-2¹ú¼Ê±ê×¼ºÍGB/T12747-2004¹ú¼Ò±ê×¼µÄÒªÇó¡£
¹«Ë¾½éÉÜ£º
More than 60 years of history
International Capacitors S.A. is a consolidated company in both Spanish and international markets thanks to many years of experience and dedication to what it has been its product par excellence along its history: the capacitor for the electrical installation. With its commercial brand name LIFASA, present in the market for more than 60 years and a constant technical and technological evolution, it has succeeded in getting adapted continuously to the progress and market requirements nowadays.
LIFASA capacitors are present in the market since 1949. More than 50 % are exported to 70 countries in five continents. Capacitors are manufactured according to European and other International Standards. They have obtained large number of certificates and approvals.
60¶àÄêµÄ¹«Ë¾ÀúÊ·
International Capacitors S.A.£¨Î÷°àÑÀ¹ú¼ÊµçÈÝÆ÷¹«Ë¾£©×÷Ϊһ¼Ò×ÛºÏÐ͹«Ë¾£¬µÃÒæÓÚ¶àÄêµÄ¾ÑéºÍ·îÏ×¾«Éñ£¬Æ¾½è׏«Ë¾·¢Õ¹ÀúÊ·ÖÐÒýÒÔΪºÀµÄµçÆø°²×°ÏµÍ³ÖеĵçÈÝÆ÷²úÆ·£¬ÎªÎ÷°àÑÀ¹úÄں͹ú¼ÊÊг¡ÌṩÁË´óÁ¿×¿Ô½µÄµçÈÝÆ÷²úÆ·¡£½èÖú³¬¹ý60ÄêÀúÊ·µÄÉÌҵƷÅÆLIFASAºÍ³ÖÐøµÄ¿Æ¼¼·¢Õ¹£¬ÏÖÔÚËüÒѾ³É¹¦µØµÃµ½³ÖÐøµÄÔö³¤ºÍÊÊÓ¦Êг¡µÄÐèÇó¡£
LIFASAµçÈÝÆ÷×Ô1949ÃæÊÐÒÔÀ´£¬³¬¹ý50%µÄ²úÆ·³ö¿Úµ½Îå´óÖÞµÄ70¸ö¹ú¼Ò¡£µçÈÝÆ÷ÊǸù¾ÝÅ·ÖÞºÍÆäËû¹ú¼Ê±ê×¼ÖÆÔìµÄ£¬»ñµÃÁË´óÁ¿µÄÖ¤ÊéºÍÅú×¼Îļþ¡£
Highest quality standards
International Capacitors S.A. has been from its beginnings a pioneering company in the promotion of the quality of its products. Since 1987, it maintains an ISO9000 Quality System periodically audited by international bodies.
At present, it has quintuple certification ISO9001:2008, ISO14001:2004, OSHAS 18001:2007, IEC QC 080000-RoHS and REACH, that guarantees the highest quality standards in its products, while they are manufactured in a way both environmentally friendly and safe and healthy for its workers. It also has energy efficiency certification ISO 50001:2011
All products included in this catalogue fully comply with the requirements of RoHS Directive.
×î¸ßµÄÖÊÁ¿±ê×¼
International Capacitors S.A.£¨Î÷°àÑÀ¹ú¼ÊµçÈÝÆ÷¹«Ë¾£©ÔçÒѲ»ÊÇÒ»¸öÒÀÀµÌáÉýÆä²úÆ·ÖÊÁ¿µÄ³õ´´¹«Ë¾¡£×Ô1987ÄêÒÔÀ´£¬Ò»Ö±»ñµÃ¹ú¼Ê×éÖ¯ÈϿɵÄISO9000ÖÊÁ¿ÌåϵÈÏÖ¤¡£
Ä¿Ç°£¬¹«Ë¾ÓµÓÐÎåÏîȨÍþÈÏÖ¤£ºISO9001:2008¡¢ISO14001:2004¡¢OSHAS 18001:2007£¬IEC QC 080000 RoHSºÍREACH£¬ÒÔÈ·±£²úÆ·µÄ×î¸ßÖÊÁ¿±ê×¼¡£Óë´ËͬʱËûÃÇΪÉú²úÕßÓªÔìÒ»¸ö¼È»·±£ÓÖ°²È«½¡¿µµÄ¹¤×÷»·¾³¡£Ëü»¹¾ßÓнÚÄÜÈÏÖ¤ 50001:2011¡£
±¾ÊÖ²áÖеÄËùÓвúÆ·¶¼ÍêÈ«·ûºÏRoHSÖ¸ÁîµÄÒªÇó¡£
Comprehensive services
The company is commited to give the best service with maximum flexibility to meet customer requirements.
Economical and technical advices.
Support in installation and commissioning.
Permanent support during the whole life of our products.
Trainig on site and in factory.
International warranty.
Every person in the company is trained and motivated to participate actively in achieving this objective.
È«·½Î»µÄ·þÎñ
¹«Ë¾ÖÂÁ¦ÓÚÒÔ×î´óµÄÁé»îÐÔÌṩ×îºÃµÄ·þÎñ£¬ÒÔÂú×ã¿Í»§µÄÒªÇó¡£
¾¼ÃºÍ¼¼Êõ½¨Òé¡£
ÔÚ°²×°ºÍµ÷ÊÔ¹ý³ÌÖÐÌṩ֧³Ö¡£
ÔÚÎÒÃDzúÆ·µÄÕû¸öÉúÃü¹ý³ÌÖÐÓÀ¾ÃÐÔµÄÖ§³Ö¡£
ÏÖ³¡ºÍ¹¤³§Åàѵ¡£
¹ú¼Ê·¶Î§Äڵı£ÐÞ¡£
¹«Ë¾ÖеÄÿһλԱ¹¤¶¼»ñµÃÁ¼ºÃµÄÅàѵ²¢»ý¼«²ÎÓëÒÔʵÏÖÕâһĿ±ê¡£
ÉϺ£É½ºÏº£ÈÚÉÌóÓÐÏÞ¹«Ë¾ÌṩÒÔÏÂÎ÷°àÑÀLIFASAÆ·ÅƵIJúÆ·£¬ÈçÓÐÐèÒª£¬»¶ÓÓëÎÒÃÇÁªÏµ¡£
µçÁ¦µçÈÝÆ÷Power capacitors
ELEFPµ¥ÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
POLTÈýÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
POLBÈýÏàÔ²ÖùÐεçÈÝÆ÷Cylindrical capacitor
FMLIµ¥ÏàÂÁµç½âµçÈÝÆ÷Pricsmatic capacitor
FML±ê×¼ÐÍÂÁµç½âµçÈÝÆ÷Standard capacitor
FML(R460)¼ÓÇ¿ÐÍÂÁµç½âµçÈÝÆ÷Reinforced capacitor
MFBÈýÏà½ô´ÕÐ͵çÈÝÆ÷Compact prismatic capacitor
FMLSÁùÏßµçÈÝÆ÷6-terminals prismatic capacitor
CPF´øÈÛ¶ÏÆ÷µÄµçÈÝÆ÷Capacitor with fuses
CPM´ø¶Ï·Æ÷µÄµçÈÝÆ÷Capacitor with breaker
CAB´øÈÛ¶ÏÆ÷ºÍ½Ó´¥Æ÷µçÈÝÆ÷Capacitor with fuse and contactor
г²¨Â˲¨Æ÷Harmonic filters
HBF-TµÚÈýг²¨Â˲¨Æ÷Third harmonic filter
TFAµÚÈýг²¨¸ôÀëÂ˲¨Æ÷Third harmonic isolation
HAFÎüÊÕÂ˹âÆ÷Absorption filter
HPF¸ßͨÂ˲¨Æ÷High pass filter
SINAF 2.0ÓÐÔ´Â˲¨Æ÷Active filter
ÐÂÐ͵çÈÝÆ÷ʽ½Ó´¥Æ÷KMLϵÁÐContactor for Capacitors
µçÈÝÆ÷¹ñAutomatic Banks
BATM080 Automatic Banks
BATLV180 Automatic Banks
BATLV360 Automatic Banks
BATLV400 Automatic Banks
BATLV480 Automatic Banks
BATLV800 Automatic Banks
BATLV1200 Automatic Banks
BATLV1600 Automatic Banks
BATLVF080´ø±ê×¼µçÈÝÆ÷
BATLVF400´ø±ê×¼µçÈÝÆ÷
BATLVF600´ø±ê×¼µçÈÝÆ÷
BATLVF800´ø±ê×¼µçÈÝÆ÷
BATLVF1000´ø±ê×¼µçÈÝÆ÷
BATLVF1200´ø±ê×¼µçÈÝÆ÷
BATLVFS400´ø¾§Õ¢¹ÜThyristors
BATLVFS600´ø¾§Õ¢¹ÜThyristors
BATLVFS800´ø¾§Õ¢¹ÜThyristors
BATLVFS1000´ø¾§Õ¢¹ÜThyristors
BATLVFS1200´ø¾§Õ¢¹ÜThyristors
·À»¤Â˲¨Æ÷Protection filters
INA/INR±ê×¼µçÈÝÆ÷¹ñµç¿¹Æ÷£¨Reactor for standard capacitor bank£©
INAS/INRS¾²Ì¬µçÈÝÆ÷¹ñµç¿¹Æ÷£¨Reactor for static bank£©
FMLFг²¨±£»¤µçÈÝÆ÷Capacitor for harmonic protection
FMLS¾²Ì¬Â˲¨µçÈÝÆ÷Capacitor for static filter
ÎÞ¹¦¹¦ÂÊ¿ØÖÆÆ÷Reactive power controllers
MCE ADV±ê×¼¿ØÖÆÆ÷Standard controller
MCE-F PLUS¾²Ì¬¹ñ¿ØÖÆÆ÷£¨Controller static bank£©
PFCL ELITE¸ß¼¶¿ØÖÆÆ÷ADVANCED CONTROLLER
¸½¼þAccessories and auxiliary
·Åµçµç×è¡¢±äѹÆ÷¡¢¼ÌµçÆ÷
TCPµçÁ÷»¥¸ÐÆ÷Current transformer with split-core
MCµçÈݽӴ¥Æ÷Contator for capacitor
CTF-CTB¾²Ì¬¿ª¹ØÄ£¿éStatic switching module
MCA PLUSÍøÂç·ÖÎöÒÇNetwork analyser
MOD-RACK´ø±ê×¼µçÈÝÆ÷µÄ°²×°¼ÜRack-mounting
µç»úºÍÕÕÃ÷µçÈÝÆ÷MOTOR AND LIGHTING CAPACITORS
µç»úÔËÐеçÈÝÆ÷MOTOR RUN CAPACITORS
ÕÕÃ÷ÓõçÈÝÆ÷LIGHTING CAPACITORS