伊顿断路器LD3600F STYLE:6613C98G22
伊顿断路器LD3600F STYLE:6613C98G22
产品价格:¥6(人民币)
  • 规格:123
  • 发货地:厦门
  • 品牌:
  • 最小起订量:1个
  • 诚信商家
    会员级别:钻石会员
    认证类型:企业认证
    企业证件:通过认证

    商铺名称:厦门纪扬科技有限公司

    联系人:李经理(先生)

    联系手机:

    固定电话:

    企业邮箱:624232572@qq.com

    联系地址:厦门市翔安区鼓岩路1号华论国际1003室

    邮编:361000

    联系我时,请说是在智能安防网上看到的,谢谢!

    商品详情
      54-44-90 O2 Oxygen
      54-44-01 CO Carbon Monoxide
      54-44-02 H2S Hydrogen Sulfide
      54-44-03 SO2 Sulfur Dioxide
      54-52-01 CO Carbon Monoxide
      54-52-02 H2S Hydrogen Sulfide
      54-45-90 O2 Oxygen
      54-45-01 CO Carbon Monoxide  
      54-45-05 CO+ CO Plus  
      54-45-19 CO-H CO Minus  
      54-45-02 H2S Hydrogen Sulfide  
      54-45-03 SO2 Sulfur Dioxide  
      54-45-21 NH3 Ammonia  
      54-45-18 Cl2 Chlorine (specific)  
      54-45-09 NO2 Nitrogen Dioxide  
      54-45-10 HCN Hydrogen Cyanide  
      54-45-13 PH3 Phosphine  
      54-47-90 O2 Oxygen (2 years) 0 – 30%/Vol. 0.1%
      54-47-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-47-05 CO+ CO Plus dual purpose CO: 0 – 1000 PPM 1 PPM
      CO/H2S (provides a H2S: 0 – 200 PPM 1 PPM
      non-specific readout
      for CO and H2S)
      54-47-19 CO-H CO Minus, reduced 0 – 1000 PPM 1 PPM
      sensitivity to H2
      54-47-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-47-03 SO2 Sulfur Dioxide 0 – 20 PPM 0.1 PPM
      54-47-21 NH3 Ammonia 0 – 100 PPM 1 PPM
      54-47-18 Cl2 Chlorine (specific) 0 – 20 PPM 0.1 PPM
      54-47-09 NO2 Nitrogen Dioxide 0 – 20 PPM 0.1 PPM
      54-47-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.1 PPM
      54-47-13 PH3 Phosphine 0 – 20 PPM 0.01 PPM
      54-47-03 SO2 Sulfur Dioxide 0 – 100 PPM 0.1 PPM
      54-46-101 Replacement sensor filter.
      35-964 Lanyard for ToxiLtd and
      ToxiPro.
      54-46-102 Replacement belt clip for
      ToxiLtd and ToxiPro.
      54-46-103 Replacement clothes clip for
      ToxiLtd and ToxiPro.
      54-46-109 Replacement cell phone-style
      swivel clip.
      54-46-104 Manual sample draw kit.
      Includes adapter, probe, and 10'
      tubing. Not for use with Cl2.
      54-46-105 Case for Value Pack. Foam-lined
      case, with room for 1 compact
      sized calibration gas cylinder.
      54-46-106 Calibration/sample draw
      adapter.
      54-46-107 Calibration adapter. Includes
      FEP lined tubing for reactive
      gases (NH3, Cl2, HCN and
      NO2).
      54-46-108 ToxiPro datalogger upgrade.
      Field upgradeable.
      54-26-0603 ToxiPro BioTrak Software Kit.
      Includes BioTrak software and
      manual.
      54-37-90 O2 Oxygen
      54-37-01 CO Carbon Monoxide  
      54-37-05 CO+ “CO Plus”  
      54-37-19 CO-H CO Minus, reduced sensitivity to H2  
      54-37-02 H2S Hydrogen Sulfide  
      54-37-03 SO2 Sulfur Dioxide  
      54-37-21 NH3 Ammonia  
      54-37-08 Cl2 Chlorine (non-specific)  
      54-37-18 Cl2 Chlorine (specific)  
      54-37-09 NO2 Nitrogen Dioxide  
      54-37-10 HCN Hydrogen Cyanide  
      54-37-13 PH3 Phosphine  
      54-37-80A LEL LEL (Alkaline)  
      54-37-80ND   LEL LEL (Rechargeable)  
      54-39-90 O2 Oxygen (2 years) 0 – 30%/Vol. 0.1%
      54-39-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-39-05 CO+ Dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
      Provides a non-specific H2S: 0 – 200 PPM 1 PPM
      readout for CO and H2S
      54-39-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
      to H2
      54-39-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-39-03 SO2 Sulfur Dioxide 0 – 100 PPM 0.1 PPM
      54-39-21 NH3 Ammonia 0 – 100 PPM 1 PPM
      54-39-08 Cl2 Chlorine (non-specific) 0 – 20 PPM 0.1 PPM
      54-39-18 Cl2 Chlorine (specific) 0 – 20 PPM 0.1 PPM
      54-39-09 NO2 Nitrogen Dioxide sensor 0 – 20 PPM 0.1 PPM
      54-39-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.1 PPM
      54-39-13 PH3 Phosphine 0 – 10 PPM 0.01 PPM
      54-38-03 Rubber boot.
      54-38-04 Toxi Vision PC programming
      kit. Includes software and
      serial interface cable.
      35-964 Lanyard for Toxi Vision.
      54-38-05 Replacement belt clip.
      54-38-06 Manual sample draw kit.
      Includes adapter, probe, and
      10  tubing Not for use with
      Cl2.
      54-38-07 Case for Value Pack. Foamlined
      case, with room for 1
      compact sized calibration
      gas cylinder.
      54-38-01 Calibration/sample draw
      adapter.
      54-38-09 Calibration adapter. Includes
      FEP lined tubing for reactive
      gases (NH3, Cl2, HCN and
      NO2).
      54-38-11 Replacement 10-Pack
      ToxiTube Dosimeter Tubes.
      54-28-01 Carbon Monoxide (CO)
      (35 and 100 ppm)
      54-28-01-C Carbon Monoxide (CO)
      (25 and 100 ppm)
      54-28-02 Hydrogen Sulfide (H2S)
      (10 and 20 ppm)
      10-384 Bump test adapter for
      Mighty-Tox
      54-48-300 LEL/O2            
      54-48-301 LEL/O2/CO            
      54-48-302 LEL/O2/H2S            
      54-48-314 LEL/O2/Duo-Tox (CO/H2S)            
      54-49-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
      54-49-90 O2 Oxygen 0 – 30%/Vol. 0.1%
      54-49-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-49-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-49-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
      (Provides Substance specific H2S: 0 – 200 PPM 1 PPM
      readouts for CO and H2S)
      54-49-200 MultiPro sensor exchange set. O2, LEL, Duo-Tox  
      54-49-201 MultiPro sensor exchange set. O2, LEL, CO  
      54-49-202 MultiPro sensor exchange set. O2, LEL, H2S  
      54-49-102 Continuous sample pump for
      MultiPro. Includes 10  of sample
      tubing and sample probe
      assembly.
      54-49-104 Sample draw/calibration
      adapter.
      54-49-105 Sample draw kit. Includes
      adapter, squeeze bulb, 10  of
      tubing and sample probe
      assembly.
      54-05-A0403 Sample probe assembly. Does
      not include tubing, squeeze
      bulb, or sample draw adapter.
      54-05-A0405 Sample probe assembly with
      11.5-inch stainless-steel probe
      tube. Does not include tubing,
      squeeze bulb, or sample draw /
      calibration adapter.
      54-49-103-1 Slip-in fast charger (110 VAC)
      for MultiPro. Includes “wallcube”
      supply.
      54-49-103-12 Slip-in fast charger (12 VDC)
      for MultiPro. Includes “cigarette
      lighter” style adapter and vehicle
      mounting hardware.
      54-49-106 MultiPro Alkaline battery pack.
      54-49-107 MultiPro Li-Ion rechargeable
      battery pack.
      54-26-0603 MultiPro BioTrak Software Kit.
      Includes BioTrak software and
      manual.
      54-26-0605S Infrared communication device
      (Serial – IrDA). Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA). Requires one
      USB port.
      54-49-110 MultiPro datalogger upgrade.
      Field upgradeable.
      54-40-30000 LEL/O2          
      54-40-30100 LEL/O2/CO          
      54-40-30200 LEL/O2/H2S          
      54-40-30102 LEL/O2/CO/H2S          
      54-42-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
      54-42-90 O2 Oxygen 0 – 30%/Vol. 0.1%
      54-42-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-42-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-42-101 MultiVision Exchange set of 4 sensors.
      O2, LEL, CO and H2S  
      54-41-004B MultiVision Rubber Boot.
      Black.
      54-41-004R MultiVision Rubber Boot.
      Red.
      54-41-004Y MultiVision Rubber Boot.
      Yellow.
      54-41-007 MultiVision Manual Sample
      draw kit. Includes adapter,
      squeeze bulb, 10  of tubing.
      54-41-008 MultiVision BioTrak Download
      software. Requires MultiVision
      datalogging option be installed.
      Computer must support
      infrared communication (IrDA)
      to download.
      54-26-0605S Infrared communication device
      (Serial – IrDA) – Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) – Requires one
      available USB port.
      54-41-001 MultiVision Calibration
      Adapter.
      54-41-005 MultiVision Remote Sampling
      Adapter (Manual sample draw).
      54-41-003 MultiVision Remote Sampling
      Adapter (Internal pump).
      Includes pump activation magnet.
      Requires internal pump to
      be installed in MultiVision.
      54-41-006 MultiVision Internal Pump
      Upgrade. Must be returned to
      Biosystems service department.
      This part number includes
      labor charges for upgrade.
      Does not include freight.
      54-41-007 MultiVision Manual sample
      draw kit. Includes adapter,
      squeeze bulb, 10  of tubing and
      sample probe assembly.
      54-05-A0403 Sample probe assembly. Does
      not include tubing, squeeze
      bulb, or sample draw adapter.
      54-05-A0405 Sample probe assembly with
      11.5-inch stainless-steel probe
      tube. Does not include tubing,
      squeeze bulb, or sample draw /
      calibration adapter.
      54-41-002 MultiVision Slip-in fast charger
      (110 VAC). Includes “wall cube”
      supply.
      54-41-010 MultiVision Slip-in fast charger
      (12 VDC). Includes “cigarette
      lighter” style adapter, and vehicle
      mounting hardware.
      54-41-011 MultiVision Five instrument
      110 VAC slip-in multi-charger.
      Includes power supply.
      35-0488 MultiVision Alkaline Battery
      Pack.
      35-0489 MultiVision NiMH Battery
      Pack.
      54-41-016 MultiVision PC programming
      kit. Used for instrument configuration
      only. Includes software
      and serial interface cable.
      54-41-014 MultiVision Datalogger and
      infrared communication (IrDA)
      upgrade. Must be returned to
      Biosystems service department.
      Includes labor charges for
      upgrade. Does not include
      freight.
      54-41-008 MultiVision BioTrak Download
      software. Requires MultiVision
      datalogging option be installed.
      Computer must support
      infrared communication (IrDA)
      to download.
      54-26-0605S Infrared communication device
      (Serial – IrDA) – Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) – Requires one
      available USB port.
      13-230 MultiVision Reference Manual.
      13-232 MultiVision Quick Reference
      Card.
      22-165 MultiVision training video.
      22-166 MultiVision training CD-ROM.
      54-41-004B MultiVision Rubber Boot.
      Black.
      54-41-004R MultiVision Rubber Boot.
      Red.
      54-41-004Y MultiVision Rubber Boot.
      Yellow.
      42-010 Shoulder Strap.
      54-41-012 MultiVision Case for Value
      Pack. Foam-lined case, with
      room for 1 compact sized calibration
      gas cylinder.
      35-0259 MultiVision Case for Confined
      Space Kit. Foam-lined, waterproof
      Pelican   style case with
      room for one standard sized
      calibration gas cylinder.
      54-41-013 MultiVision Calibration kit.
      Includes foam-lined carrying
      case with room for up to three
      cylinders of calibration gas. Kit
      contains 12-023 regulator and
      other fittings. Kit does not
      include gas.
      54-41-V9045 MultiVision Value Pack “Makeup”
      Kit. Includes Value Pack
      case with 54-9045E calibration
      gas and 12-022 economy regulator.
      For use with O2/LEL and
      O2/LEL/CO configurations.
      54-41-V9047 MultiVision Value Pack “Makeup”
      Kit. Includes Value Pack
      case with 54-9047E calibration
      gas and 12-023 regulator.
      For use with O2/LEL/H2S
      configurations.
      54-41-V9049 MultiVision Value Pack “Makeup”
      Kit. Includes Value Pack
      case with 54-9049E calibration
      gas and 12-023 regulator. For
      use with O2/LEL/CO/H2S
      configurations.
      54-41-001 MultiVision Calibration
      Adapter.
      54-23-000 No Sensors Installed    
      54-23-300 LEL/O2          
      54-23-301 LEL/O2/CO          
      54-23-305 LEL/O2/CO+          
      54-23-319 LEL/O2/CO-H          
      54-23-302 LEL/O2/H2S          
      54-23-314 LEL/O2/Duo-Tox (CO/H2S)          
      54-23-303 LEL/O2/SO2 (0.0-25/0.1 ppm Incr.)        
      54-23-321 LEL/O2/NH3        
      54-23-308 LEL/O2/Cl2 (non-specific)        
      54-23-318 LEL/O2/Cl2 (specific)        
      54-23-312 LEL/O2        
      54-23-320 LEL/O2    
      54-23-309 LEL/O2/NO2        
      54-23-310 LEL/O2/HCN        
      54-23-313 LEL/O2/PH3        
      54-25-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
      54-25-90 O2 Oxygen 0 – 30%/Vol. 0.1%
      54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-25-05 CO+ CO Plus dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
      (provides a non-specific H2S: 0 – 200 PPM 1 PPM
      readout for CO and H2S)
      54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
      to H2
      54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
      (provides Substance specific H2S: 0 – 200 PPM 1 PPM
      readouts for CO and H2S)
      54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
      54-25-15 SO2-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
      54-25-04 NH3 Ammonia 0 – 50 PPM 1 PPM
      (for software versions
      prior to 2.0)
      54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
      54-25-08  Cl2 Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
      54-25-18  Cl2 Chlorine (specific) 0 – 50 PPM 0.1 PPM
      54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
      54-25-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
      54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
      54-26-0101 Continuous sample pump for
      PhD Lite. Includes 10  of
      sample tubing and sample
      probe assembly.
      54-26-0101-C Continuous sample pump for
      PhD Lite – Configured for reactive
      gas detection, such as Cl2.
      Includes 10  of inert sample
      tubing and sample probe
      assembly.
      54-26-0302 Leather holster. For PhD Lite
      without pump.
      54-26-0306 Leather holster. For PhD Lite
      with pump attached.
      54-26-0603 PhD Lite BioTrak Software Kit.
      Includes BioTrak software and
      manual.
      54-26-0605S Infrared communication device
      (Serial – IrDA) – Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) – Requires one
      available USB port.
      54-27-0802 TouchID   programming kit.
      Includes software, programming
      wand, serial connector,
      10 TouchID   buttons, 10 key
      chain/wall mounts for buttons
      and 10 TouchID   badges.
      54-26-0101 Continuous sample pump for
      PhD Lite. Includes 10  of sample
      tubing and sample probe
      assembly.
      54-26-0101-C Continuous sample pump for
      PhD Lite – Configured for reactive
      gas detection, such as Cl2.
      Includes 10’ of inert sample
      tubing and sample probe
      assembly.
      35-0344 Tubing kit for reactive gas
      detection (Cl2). Includes 10  of
      tubing plus adapters.
      54-26-0401 Sample draw kit. Includes
      adapter, squeeze bulb, 10  of
      tubing and sample probe
      assembly. Not for use with Cl2.
      54-05-A0403 Sample probe assembly. Does
      not include tubing, squeeze
      bulb, or sample draw adapter.
      54-26-0301 Sample draw/calibration
      adapter.
      54-05-A0405 Sample probe assembly with
      11.5-inch stainless-steel probe
      tube. Does not include tubing,
      squeeze bulb, or sample draw /
      calibration adapter.
      54-26-0201 Slip-in fast charger (110 VAC)
      for PhD Lite. Includes “wall
      cube” supply.
      54-26-0202 Slip-in fast charger (12 VDC)
      for PhD Lite. Includes “cigarette
      lighter” style adapter, and vehicle
      mounting hardware.
      54-26-0204 Five instrument 110 VAC slipin
      multi-charger for PhD Lite.
      Includes power supply.
      54-26-0601   Datalogger upgrade for PhD
      Lite without “Black-Box”
      recorder. (Instrument disassembly
      required.) If your non-datalogging
      PhD Lite shows the
      time and date during startup, it
      does include a “Black-Box”
      recorder.
      54-26-0606   Datalogger upgrade for PhD
      Lite with “Black-Box” recorder.
      54-26-0603 PhD Lite BioTrak Software Kit.
      Includes BioTrak software and
      manual.
      54-26-0605S Infrared communication device
      (Serial – IrDA) – Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) – Requires one
      available USB port.
      54-27-0802 TouchID   programming kit.
      Includes software, programming
      wand, serial connector, 10
      TouchID   buttons, 10 key
      chain/wall mounts for buttons
      and 10 TouchID   badges.
      54-27-0805 10 TouchID   buttons.
      54-27-0807 10 TouchID   key ring/wall
      mounts. Does not include
      TouchID   buttons.
      54-27-0810 10 TouchID   badges. Does not
      include TouchID   buttons.
      13-088 PhD Lite Reference Manual.
      13-089 PhD Lite Quick Reference Card.
      22-125 PhD Lite training video.
      22-132 PhD Lite interactive training
      CD-ROM.
      54-26-0302 Leather holster. For PhD Lite
      without pump.
      54-26-0306 Leather holster. For PhD Lite
      with pump attached.
      42-011 Wrist strap.
      42-010 Shoulder Strap.
      54-26-0404 Case for Value Pack. Foam-lined
      case, with room for 1 compact
      sized calibration gas cylinder.
      35-0259 Case for Confined Space Kit.
      Foam-lined, waterproof
      Pelican   style case with room
      for one standard sized calibration
      gas cylinder.
      54-26-0501 Calibration kit for PhD Lite.
      Includes foam-lined carrying
      case with room for up to three
      cylinders of calibration gas. Kit
      contains 12-023 regulator and
      other fittings. Kit does not
      include gas.
      54-26-V9045 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9045E calibration gas and
      12-022 economy regulator. For
      use with O2/LEL and O2 /
      LEL/CO, CO+, CO-H configurations.
      54-26-V9047 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9047E calibration gas and
      12-023 regulator. For use with
      O2/LEL/H2S configurations.
      54-26-V9049 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9049E calibration gas and
      12-023 regulator. For use with
      O2/LEL/CO/H2S and O2 /
      LEL/Duo-Tox (CO/H2S)
      configurations.
      54-26-0301 Sample draw/calibration
      adapter for PhD Lite.
      54-26-0405 Calibration adapter for use with
      reactive gases (NH3, Cl2, HCN,
      54-24-00000 No Sensors Installed    
      54-24-30000 LEL/O2          
      54-24-30100 LEL/O2/CO          
      54-24-30500 LEL/O2/CO+          
      54-24-31900 LEL/O2/CO-H          
      54-24-30200 LEL/O2/H2S          
      54-24-30102 LEL/O2/CO/H2S          
      54-24-31400 LEL/O2/Duo-Tox (CO/H2S)          
      54-24-30300 LEL/O2/ SO2        
      54-24-30103 LEL/O2/CO/ SO2        
      54-24-30203 LEL/O2/H2S/ SO2        
      54-24-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2        
      54-24-31421 LEL/O2/Duo-Tox /NH3        
      54-24-31408 LEL/O2/Duo-Tox /Cl2 (non-specific)        
      54-24-31409 LEL/O2/Duo-Tox /NO2        
      54-24-31410 LEL/O2/Duo-Tox /HCN        
      54-24-31412 LEL/O2/Duo-Tox        
      54-24-31413 LEL/O2/Duo-Tox /PH3        
      54-24-31415 LEL/O2/Duo-Tox/SO2 – Ext.        
      54-24-31418 LEL/O2/Duo-Tox /Cl2 (specific)        
      54-24-31420   LEL/O2/Duo-Tox    
      54-24-30121 LEL/O2/CO/NH3        
      54-24-30108 LEL/O2/CO/Cl2 (non-specific)        
      54-24-30109 LEL/O2/CO/NO2        
      54-24-30110 LEL/O2/CO/HCN        
      54-24-30112 LEL/O2/CO        
      54-24-30113 LEL/O2/CO/PH3        
      54-24-30115 LEL/O2/CO/ SO2 – Ext.        
      54-24-30118 LEL/O2/CO/Cl2 (specific)        
      54-24-30120   LEL/O2/CO    
      54-24-31921 LEL/O2/CO-H/NH3        
      54-24-31920   LEL/O2/CO-H    
      54-24-31421 LEL/O2/DuoTox/NH3        
      54-24-31408 LEL/O2/DuoTox/Cl2 (non specific)        
      54-24-31409 LEL/O2/DuoTox/NO2        
      54-24-31410 LEL/O2/DuoTox/HCN        
      54-24-31412 LEL/O2/DuoTox        
      54-24-31413 LEL/O2/DuoTox/PH3        
      54-24-31415 LEL/O2/DuoTox/SO2-Ext.        
      54-24-31418 LEL/O2/DuoTox/Cl2 (specific)        
      54-24-31420   LEL/O2/DuoTox    
      54-24-30121 LEL/O2/CO/NH3        
      54-24-30108 LEL/O2/CO/Cl2 (non specific)        
      54-24-30109 LEL/O2/CO/NO2        
      54-24-30110 LEL/O2/CO/HCN        
      54-24-30112 LEL/O2/CO        
      54-24-30113 LEL/O2/CO/PH3        
      54-24-30115 LEL/O2/CO/SO2-Ext.        
      54-24-30118 LEL/O2/CO/Cl2 (specific)        
      54-24-30120   LEL/O2/CO    
      54-24-31921 LEL/O2/CO-H/NH3        
      54-24-31920   LEL/O2/CO-H    
      54-24-30521 LEL/O2/CO+/NH3        
      54-24-30508 LEL/O2/CO+/Cl2 (non specific)        
      54-24-30509 LEL/O2/CO+/NO2        
      54-24-30510 LEL/O2/CO+/HCN        
      54-24-30512 LEL/O2/CO+        
      54-24-30513 LEL/O2/CO+/PH3        
      54-24-30515 LEL/O2/CO+/SO2-Ext.        
      54-24-30518 LEL/O2/CO+/Cl2 (specific)        
      54-24-30520   LEL/O2/CO+    
      54-24-30221 LEL/O2/H2S/NH3        
      54-24-30208 LEL/O2/H2S/Cl2 (non specific)        
      54-24-30209 LEL/O2/H2S/NO2        
      54-24-30210 LEL/O2/H2S/HCN        
      54-24-30212 LEL/O2/H2S        
      54-24-30213 LEL/O2/H2S/PH3        
      54-24-30215 LEL/O2/H2S/SO2-Ext.        
      54-24-30218 LEL/O2/H2S/Cl2 (specific)        
      54-24-30219 LEL/O2/H2S/CO-H        
      54-24-30220   LEL/O2/H2S    
      54-24-30321 LEL/O2/SO2/NH3        
      54-24-30305 LEL/O2/SO2/CO+        
      54-24-30308 LEL/O2/SO2/Cl2 (non specific)        
      54-24-30309 LEL/O2/SO2/NO2        
      54-24-30310 LEL/O2/SO2/HCN        
      54-24-30312 LEL/O2/SO2        
      54-24-30313 LEL/O2/SO2/PH3        
      54-24-30318 LEL/O2/SO2/Cl2 (specific)        
      54-24-30319 LEL/O2/SO2/CO-H        
      54-24-30320   LEL/O2/SO2    
      54-24-30321 LEL/O2/SO2/NH3        
      54-24-30800 LEL/O2/Cl2 (non specific)        
      54-24-30821 LEL/O2/Cl2 (non specific)/NH3        
      54-24-30809 LEL/O2/Cl2 (non specific)/NO2        
      54-24-30810 LEL/O2/Cl2 (non specific)/HCN        
      54-24-30813 LEL/O2/Cl2 (non specific)/PH3        
      54-24-30815 LEL/O2/Cl2 (non specific)/SO2-Ext.        
      54-24-30819 LEL/O2/Cl2 (non specific)/CO-H        
      54-24-30900 LEL/O2/NO2        
      54-24-30921 LEL/O2/NO2/NH3        
      54-24-30910 LEL/O2/NO2/HCN        
      54-24-30912 LEL/O2/NO2        
      54-24-30913 LEL/O2/NO2/PH3        
      54-24-30915 LEL/O2/NO2/SO2-Ext.        
      54-24-30918 LEL/O2/NO2/Cl2 (specific)        
      54-24-30919 LEL/O2/NO2/CO-H        
      54-24-30920   LEL/O2/NO2    
      54-24-31000 LEL/O2/HCN        
      54-24-31012 LEL/O2/HCN        
      54-24-31015 LEL/O2/HCN/SO2-Ext.        
      54-24-31018 LEL/O2/HCN/Cl2 (specific)        
      54-24-31019 LEL/O2/HCN/CO-H        
      54-24-31020   LEL/O2/HCN    
      54-24-31221 LEL/O2/NH3        
      54-24-31200 LEL/O2        
      54-24-31213 LEL/O2/PH3        
      54-24-31215 LEL/O2/SO2-Ext.        
      54-24-31219 LEL/O2/CO-H        
      54-24-31300 LEL/O2/PH3        
      54-24-31315 LEL/O2/PH3/SO2-Ext.        
      54-24-31318 LEL/O2/PH3/Cl2 (specific)        
      54-24-31319 LEL/O2/PH3/CO-H        
      54-24-31320   LEL/O2/PH3    
      54-24-31500 LEL/O2/SO2-Ext.        
      54-24-31521 LEL/O2/SO2-Ext./NH3        
      54-24-31518 LEL/O2/SO2-Ext./Cl2 (specific)        
      54-24-31519 LEL/O2/SO2-Ext./CO-H        
      54-24-31520   LEL/O2/SO2-Ext.    
      54-24-31800 LEL/O2/Cl2 (specific)        
      54-24-31821 LEL/O2/Cl2 (specific)/NH3        
      54-24-31819 LEL/O2/Cl2 (specific)/CO-H        
      54-24-31820   LEL/O2/Cl2 (specific)    
      54-24-32000   LEL/O2    
      54-24-32021   LEL/O2/NH3    
      54-24-32100 LEL/O2/NH3        
      54-27-0205 Slip-in fast charger (110 VAC)
      for PhD5. Includes “wall cube”
      power supply.
      54-27-0201 Slip-in fast charger/data dock
      (110 VAC) for PhD5. Includes
      “wall cube” power supply.
      54-27-0202 Slip-in fast charger (12 VDC)
      for PhD5. Includes 12 VDC
      “cigarette lighter” style adapter,
      and vehicle mounting hardware.
      54-27-0204 Five instrument 110 VAC slipin
      multi-charger for PhD5.
      Includes power supply.
      35-0219 Alkaline battery pack for PhD5.
      35-0214 NiCad battery pack for PhD5.
      54-27-0601   Datalogger upgrade for PhD5
      without “Black-Box” recorder.
      (Requires instrument disassembly.)
      (If your non-datalogging
      PhD5 shows the time and date
      during startup, it does include a
      “Black-Box” recorder.)
      54-27-0607   Datalogger upgrade for PhD5
      with “Black-Box” recorder.
      (If your non-datalogging PhD5
      shows the time and date during
      startup, it does include a
      “Black-Box” recorder.)
      54-27-0603 BioTrak Software Kit. Includes
      computer cable, software and
      manual.
      54-27-0605 PhD5 Datalink Kit. Includes
      download cradle, BioTrak
      software, computer cable and
      manual.
      54-27-0802 TouchID   programming kit.
      Includes software, programming
      wand, serial connector,
      10 buttons, 10 key chain/wall
      mounts for TouchID   buttons
      and 10 TouchID   badges.
      54-27-0805 10 TouchID   buttons.
      54-27-0807 10 TouchID   key ring/wall
      mounts. Does not include
      TouchID   buttons.
      54-27-0810 10 TouchID   badges. Does not
      include TouchID   buttons.
      54-25-80A LEL Combustible gas 0 – 100% LEL 1% LEL
      54-04-90 O2 Oxygen 0 – 30%/Vol. 0.1%
      54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-25-05 CO+ CO Plus dual purpose CO/H2S CO: 0 – 1000 PPM 1 PPM
      (provides a non-specific H2S: 0 – 200 PPM 1 PPM
      readout for CO and H2S)
      54-25-19 CO-H CO Minus, reduced sensitivity 0 – 1000 PPM 1 PPM
      to H2
      54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
      (provides substance specific H2S: 0 – 200 PPM 1 PPM
      readouts for CO and H2S)
      54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
      54-25-15 SO2-Ext. Sulfur Dioxide extended range 0 – 100 PPM 1 PPM
      54-25-04 NH3 Ammonia 0 – 50 PPM 1 PPM
      (for software versions
      prior to 2.0)
      54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
      54-25-08  Cl2 Chlorine (non-specific) 0 – 50 PPM 0.1 PPM
      54-25-18  Cl2 Chlorine (specific) 0 – 50 PPM 0.1 PPM
      54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
      54-25-10 HCN Hydrogen Cyanide 0 – 100 PPM 0.2 PPM
      54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
      13-092 PhD5 Reference Manual.
      13-093 PhD5 Quick Reference Card.
      22-130 PhD5 training video.
      22-131 PhD5 interactive training
      CD-ROM.
      42-005 Shoulder strap for PhD5.
      45-016 Leather weather cover for
      PhD5.
      56-282 Leather weather cover for
      PhD5 with TouchID  .
      PhD5 Calibration Materials and
      Carrying Cases
      PART NO. DESCRIPTION
      54-27-0401 Case for Value Pack. Foamlined
      case, with room for
      1 compact sized calibration
      gas cylinder.
      35-0002 Case for Confined Space Kit.
      Foam-lined, waterproof
      Pelican   style case with room
      for one standard sized
      calibration gas cylinder.
      54-27-0501 Calibration kit for PhD5.
      Includes foam-lined carrying
      case with room for up to three
      cylinders of calibration gas.
      Kit contains 12-023 regulator
      and other fittings. Kit does not
      include gas.
      54-27-V9045 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9045E calibration gas and
      12-022 regulator. For use with
      O2/LEL; O2/LEL/CO and
      O2/LEL/CO+ configurations.
      54-27-V9047 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9047E calibration gas and
      12-023 regulator. For use with
      O2/LEL/H2S configurations.
      54-27-V9049 Value Pack “Make-up” Kit.
      Includes Value Pack case with
      54-9049E calibration gas and
      12-023 regulator. For use with;
      O2/LEL/CO/H2S and O2 /
      LEL/Duo-Tox (CO/H2S)
      configurations.
      10-263 Sample draw/calibration
      adapter for PhD5.
      54-05-A0409 Calibration adapter for use
      with reactive gases (NH3,
      Cl2, HCN, NO2).
      54-34-00000 No Sensors Installed    
      54-34-30000 LEL/O2    
      54-34-30100 LEL/O2/CO    
      54-34-31900 LEL/O2/CO-H    
      54-34-30200 LEL/O2/H2S    
      54-34-31400 LEL/O2/Duo-Tox (CO/H2S)    
      54-34-30102 LEL/O2/CO/H2S    
      54-34-30300 LEL/O2/SO2    
      54-34-30103 LEL/O2/CO/SO2    
      54-34-30203 LEL/O2/H2S/SO2    
      54-34-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2    
      54-34-31500 LEL/O2/SO2 Ext.    
      54-34-32100 LEL/O2/NH3    
      54-34-30800 LEL/O2/Cl2 (non-specific)    
      54-34-31800 LEL/O2/Cl2 (specific)    
      54-34-31200 LEL/O2    
      54-34-32000 LEL/O2    
      54-34-30900 LEL/O2/NO2    
      54-34-50000 HC-PPM LEL/O2    
      54-34-50100 HC-PPM LEL/O2/CO    
      54-34-51400 HC-PPM LEL/O2/Duo-Tox (CO/H2S)    
      54-34-50102 HC-PPM LEL/O2/CO/H2S    
      54-35-00000 No Sensors Installed    
      54-35-30000 LEL/O2    
      54-35-30100 LEL/O2/CO    
      54-35-31900 LEL/O2/CO-H    
      54-35-30200 LEL/O2/H2S    
      54-35-31400 LEL/O2/Duo-Tox (CO/H2S)    
      54-35-30102 LEL/O2/CO/H2S    
      54-35-30300 LEL/O2/SO2    
      54-35-30103 LEL/O2/CO/SO2    
      54-35-30203 LEL/O2/H2S/SO2    
      54-35-31403 LEL/O2/Duo-Tox (CO/H2S)/SO2    
      54-35-31500 LEL/O2/SO2 Ext.    
      54-35-32100 LEL/O2/NH3    
      54-35-30800 LEL/O2/Cl2 (non-specific)    
      54-35-31800 LEL/O2/Cl2 (specific)    
      54-35-31200 LEL/O2    
      54-35-32000 LEL/O2    
      54-35-30900 LEL/O2/NO2    
      54-35-50000   HC-PPM LEL/O2    
      54-35-50100   HC-PPM LEL/O2/CO    
      54-35-51400   HC-PPM LEL/O2/Duo-Tox (CO/H2S)    
      54-35-50102   HC-PPM LEL/O2/CO/H2S    
      54-25-80 LEL Combustible Gas 0 – 100% LEL 1% LEL
      54-25-70 LEL Combustible Gas 0 – 100% LEL 1% LEL
      54-25-71 HC-PPM LEL Combustible Gas 0 – 100% LEL see note  
      54-25-90 O2 Oxygen 0 – 30%/Vol. 0.1%
      54-25-01 CO Carbon Monoxide 0 – 1000 PPM 1 PPM
      54-25-05 CO+ CO Plus dual purpose CO: 0 – 1000 PPM 1 PPM
      CO/H2S (provides a H2S: 0 – 200 PPM 1 PPM
      non-specific readout
      for CO and H2S)
      54-25-19 CO-H CO Minus, reduced 0 – 1000 PPM 1 PPM
      sensitivity to H2
      54-25-02 H2S Hydrogen Sulfide 0 – 200 PPM 1 PPM
      54-25-14 Duo-Tox Dual Channel CO/H2S CO: 0 – 1000 PPM 1 PPM
      (provides Substance H2S: 0 – 200 PPM 1 PPM
      specific readouts
      for CO and H2S)
      54-25-03 SO2 Sulfur Dioxide 0 – 25 PPM 0.1 PPM
      54-25-15 SO2-Ext. Sulfur Dioxide 0 – 100 PPM 1 PPM
      extended range
      54-25-21 NH3 Ammonia 0 – 100 PPM 1 PPM
      54-25-08  Cl2 Chlorine 0 – 50 PPM 0.1 PPM
      (non-specific)
      54-25-18  Cl2 Chlorine 0 – 50 PPM 0.1 PPM
      (specific)
      54-25-09 NO2 Nitrogen Dioxide 0 – 50 PPM 0.1 PPM
      54-25-13 PH3 Phosphine 0 – 20 PPM 0.1 PPM
      54-25-06 NO Nitric Oxide 0 – 350 PPM 1 PPM
      35-0379 Cannonball3 motorized sample
      draw pump module.
      35-0378 Cannonball3 motorized sample
      draw pump module for dual
      pump version (2 pumps). The
      Cannonball3 must be configured
      for dual pump.
      35-0376 Cannonball3 Alkaline battery
      pack (“D”-Cell batteries not
      included).
      35-0377 Cannonball3 NiMH battery
      pack.
      54-26-0603 Cannonball3 BioTrak Software
      Kit. Includes BioTrak software
      and manual.
      54-26-0605S Infrared communication device
      (Serial – IrDA) – Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) – Requires one
      available USB port.
      54-27-0802 TouchID   programming
      kit. Includes software,
      programming wand, serial
      connector, 10 buttons,
      10 key chain/wall mounts
      for TouchID   buttons and
      10 TouchID   badges.
      35-0379 Cannonball3 motorized sample
      draw pump.
      35-0378 Cannonball3 motorized sample
      draw pumps for dual pump version.
      The Cannonball3 must be
      configured for dual pump.
      54-36-03 Cannonball3 Sample probe with
      plastic extension and male
      quick disconnect.
      54-36-04 Cannonball3 Sample probe with
      stainless steel extension and
      male quick disconnect.
      54-36-05 Cannonball3 Sample probe with
      plastic extension and threaded
      for quick disconnect fitting.
      54-36-06 Cannonball3 Sample probe with
      stainless steel extension and
      threaded for quick disconnect
      fitting.
      54-36-07 Cannonball3 Sample probe
      male quick disconnect.
      54-36-08-010 Cannonball3 Extension hose, 10
      feet with male and female quick
      disconnect.
      54-36-08-025 Cannonball3 Extension hose, 25
      feet with male and female quick
      disconnect.
      54-36-08-050 Cannonball3 Extension hose, 50
      feet with male and female quick
      disconnect.
      54-36-08-100 Cannonball3 Extension hose,
      100 feet with male and female
      quick disconnect.
      54-36-09 Cannonball3 set of male and
      female quick disconnects.
      54-36-10 Cannonball3 Snap-on fast
      charger (110VAC).
      54-36-11 Cannonball3 Snap-on fast
      charger (12VDC).
      35-0376 Cannonball3 Alkaline battery
      pack (batteries not included).
      35-0377 Cannonball3 NiMH battery
      pack.
      54-36-13   Cannonball3 Datalogger
      upgrade.
      54-26-0603 Cannonball3 BioTrak Software
      Kit. Includes BioTrak software
      and manual.
      54-26-0605S Infrared communication device
      (Serial – IrDA) - Requires one
      available PC serial port.
      54-26-0605U Infrared communication device
      (USB – IrDA) - Requires one
      available USB port.
      54-27-0802 TouchID   programming kit.
      Includes software, programming
      wand, serial connector, 10
      buttons, 10 key chain/wall
      mounts for TouchID   buttons
      and 10 TouchID   badges.
      54-27-0805 10 TouchID   buttons.
      54-27-0807 10 TouchID   key ring/wall
      mounts. Does not include
      TouchID   buttons.
      54-27-0810 10 TouchID   badges. Does not
      13-173 Cannonball3 Reference Manual.
      31-292 Cannonball3 Quick Reference
      Label.
      22-143 Cannonball3 Training Video.
      42-002 Cannonball3 Shoulder strap.
      54-36-20 Cannonball3 Gasket service kit.
      Includes 6 filter gaskets, 2
      pump gasket, 2 battery gasket
      and lubricant for gaskets.
      54-36-17 Internal filter kit for
      Cannonball3. (10 ea. particulate
      and 5 ea. hydrophobic).
      54-36-14 Cannonball3 Calibration kit.
      Includes foam-lined carrying
      case with room for up to three
      cylinders of calibration gas. Kit
      contains 12-023 regulator and
      other fittings. Kit does not
      include gas.
      35-0453 Cannonball3 Waterproof
      Pelican   style carrying case
      with room for one Cannonball3
      and one cylinder of calibration
      gas.
      54-36-15 Cannonball3 Calibration tube
      with male quick disconnect.
      54-36-18 Cannonball3 Calibration balloon
      (not for use with Cl2).
      54-36-16 Cannonball3 Inert calibration
      tube (for reactive gases) with
      male quick disconnect.
      54-46-9000 IQ Express Docking Station
      for O2, CO, H2S, SO2 with
      Software, Installation Disks,
      and Manuals.
      54-46-9000N Network Compatible.
      54-46-9100 Enhanced IQ Express Docking
      Station for O2, CO, H2S, SO2,
      Cl2, NO2, NH3, HCN, PH3
      with Software, Installation
      Disks, and Manuals.
      54-46-9100N Network Compatible.
      54-46-8000 Mounting Bracket.
      54-46-8001 Powered Mounting Bracket.
      54-43-0x0yz IQ Controller with IQ controller
      software, installation
      disks and manuals. Please
      complete part number using
      the IQ Controller options
      matrix below. Note some
      options affect the price of the
      controller.
      54-43-201 IQ Database Manager software.
      Note this software is
      included with the IQ
      Controller above.
      54-43-1401   IQ Dock for MultiVision.
      54-43-1231 IQ Dock for PhD Lite.
      54-43-1241 IQ Dock for PhD5.
      54-43-1341 IQ Dock for Cannonball3.
      54-43-1481 IQ Dock for MultiPro.
      54-43-1021 IQ Dock for PhD Ultra.
      54-43-200 IQ DataLink software, installation
      disks and manuals.
      Supports PhD Lite, PhD5,
      PhD Ultra, MultiVision
      (Datalog ging) and Cannonball3.
      Note communication
      hardware is not included.
      54-43-201 IQ Database Manager software.
      Note this software is
      included with the IQ DataLink
      software package above.
      54-43-202 IQ DataLink software with
      serial download cradle, installation
      disks and manuals.
      Same as P/N 54-43-200, but
      also includes PhD5 (PhD
      Ultra) charger and download
      cradle, with serial cable and
      power supply.
      54-43-203 IQ DataLink software with
      IrDA (Serial), installation disks
      and manuals. Same as P/N
      54-43-200, but also includes a
      Serial – IrDA communication
      device and download cradle.
      IrDA communication is
      required for PhD Lite, Multi -
      Vision (datalogging) and
      MultiPro.
      54-43-204 IQ DataLink software with,
      IrDA (USB), installation disks
      and manuals. Same as
      P/N 54-43-200, but also
      includes a Serial – IrDA
      communication device and
      download cradle. IrDA communication
      is required for
      PhD Lite, Multi Vision (datalogging)
      and MultiPro.
      54-9041 Methane 50% LEL 50 ppm 5 years 103 liters
      54-9043   Methane 50% LEL 50 ppm 25 ppm 1 year 58 liters
      54-9042E Propane Equivalent 50% LEL 50 ppm 5 years 103 liters
      54-9045E Propane Equivalent 50% LEL 50 ppm 5 years 34 liters
      54-9044E   Propane Equivalent 50% LEL 50 ppm 25 ppm 1 year 58 liters
      54-9049E   Propane Equivalent 50% LEL 50 ppm 25 ppm 1 year 34 liters
      54-9048E Propane Equivalent 50% LEL 25 ppm 1 year 58 liters
      54-9047E Propane Equivalent 50% LEL 25 ppm 1 year 34 liters
      54-9070E Pentane Equivalent 50% LEL 50 ppm 5 years 103 liters
      54-9046E Pentane Equivalent 50% LEL 50 ppm 25 ppm 1 year 58 liters
      54-9071E Pentane Equivalent 50% LEL 50 ppm 5 years 34 liters
      54-9031 LEL Methane 50% LEL 5 Years 103 liters
      54-9032E LEL Propane Equivalent 50% LEL 5 Years 103 liters
      54-9068E LEL Pentane Equivalent 50% LEL 5 Years 103 liters
      54-9066 LEL Hydrogen (H2) 50% LEL 5 Years 103 liters
      54-9033 CO Carbon Monoxide 50 ppm 5 Years 103 liters
      54-9036 CO Carbon Monoxide 50 ppm 5 Years 34 liters
      54-9067 CO Carbon Monoxide 125 ppm 5 Years 103 liters
      (Mighty-Tox series
      bump test only)
      54-9034 H2S Hydrogen Sulfide 25 ppm 1 Year 58 liters
      54-9057 H2S Hydrogen Sulfide 25 ppm 1 Year 34 liters
      54-9037 SO2 Sulfur Dioxide 10 ppm 1 Year 58 liters
      54-9058 SO2 Sulfur Dioxide 10 ppm 1 Year 34 liters
      54-9051   NH3 Ammonia 50 ppm 1 Year 58 liters
      54-9061   NH3 Ammonia 50 ppm 1 Year 34 liters
      54-9052 Cl2 Chlorine 5 ppm 8 Months 58 liters
      54-9062 Cl2 Chlorine 5 ppm 8 Months 34 liters
      54-9056 NO2 Nitrogen Dioxide 5 ppm 6 Months 58 liters
      54-9059 NO2 Nitrogen Dioxide 5 ppm 6 Months 34 liters
      54-9054 HCN Hydrogen Cyanide 10 ppm 1 Year 58 liters
      54-9053 HCl Hydrogen Chloride 10 ppm 1 Year 58 liters
      54-9065 PH3 Phosphine 5 ppm 6 Months 58 liters
      54-9073 PH3 Phosphine 5 ppm 6 Months 34 liters
      54-9064 H2 Hydrogen 100 ppm 5 Years 103 liters
      54-9035 N2 Nitrogen 99.9% 5 Years 103 liters
      54-9039 O2 Oxygen (Zero Air) 20.9% 5 Years 103 liters
      12-022 Regulator, 1.0 liter per minute
      flow. Only for use with 54-9036
      54-9045E and 54-9071E
      calibration gas cylinders.
      12-023 Regulator, standard service 1.0
      liter per minute flow.
      12-025 Regulator, ammonia service 1.0
      liter per minute flow.
      12-030 Regulator, standard service 1.0
      liter per minute flow with on/off
      knob.
      12-039 Demand flow regulator, standard
      service, 0 – 3 liters per minute
      flow.
      35-0380 AirChek 3000 PSI Regulator. 1.0
      liter per minute regulator with
      CGA346 hand-wheel coupling.
      54-04-80 LEL Combusible Gas    
      54-04-90 O2 Oxygen    
      54-04-01 CO Carbon Monoxide    
      54-04-02 H2S Hydrogen Sulfide    
      54-04-03 SO2 Sulfur Dioxide    
      54-04-04 NH3 Ammonia  
      54-04-05 CO+ Dual purpose CO/H2S    
      (provides a non-specific readout
      for CO and H2S)
      54-04-08 Cl2 Chlorine  
      54-04-09 NO2 Nitrogen Dioxide  
      54-04-10 HCN Hydrogen Cyanide  
      (special version of PhD Ultra required)
      54-04-13 PH3 Phosphine  
      3101 Oxygen sensor for Model 3100.
      3102 Remote Oxygen sensor for Model
      3100R.
      3301 Carbon monoxide sensor, CO for
      Models 3300 and 3300-TP.
      3350 Compressed air sampling kit with
      fixed flow regulator. Rated 10 –
      200 psig. Specify 3/8" Hansen “-
      H” or 3/8" Schraeder “-S” male
      QD fitting when ordering.
      35-179 Air sampling assembly (sensor/
      calibration adapter and tubing).
      35-043 Battery Eliminator (110 VAC).
      35-197 Relay Closure, simply closes a circuit
      upon alarm condition, rated
      at no more than 110 VAC and 1
      amp service. Factory installation
      required, must be specified at
      time of purchase.
      6050 High-intensity remote alarm (115
      dBA @ 12") Includes mounting
      plate, 9V battery, test button, 6  of
      cable Not intrinsically safe; may
      not be used in potentially combustible
      environments.
      55-025 Wall mounting plate for
      3300-TP. Accepts monitor
      mounted bracket.
      54-16-90 O2 Oxygen      
      54-16-80 LEL Combustible  
      54-16-01 CO Carbon Monoxide      
      54-16-02 H2S Hydrogen Sulfide      
      54-16-03 SO2 Sulfur Dioxide      
      54-16-08 Cl2 Chlorine    
      54-16-13 PH3 Phosphine      
      54-16-09 NO2 Nitrogen Dioxide      
      54-15-801-S LEL Combustible
      54-1631 O2 Oxygen
      54-1632 H2S Hydrogen Sulfide
      54-1634 CO Carbon Monoxide
      54-1635 Cl2 Chlorine
      54-1636 SO2 Sulfur Dioxide
      54-1637 NO2 Nitrogen Dioxide
      54-17-A0101 Single integrally mounted
      external strobe for ZoneGuard
      (Red).
      54-17-A0103 Single integrally mounted
      external strobe for ZoneGuard
      (Amber).
      54-17-A0102 Dual integrally mounted
      external strobes for ZoneGuard
      (Red and Amber).
      54-17-A0201 Remote programmable (volume
      adjustable) audible alarm.
      54-17-A0202 Remote high intensity audible
      alarm.
      54-17-A0301 Splash guard for sensors
      installed in explosion proof
      remote housings.
      54-17-A0302 Splash guard for sensors
      installed in standard housings.
      54-17-A0401 Wire, 22 gauge, 6 conductor,
      twisted pair, shielded with
      drain, used to connect Oxygen
      remote detectors with
      ZoneGuard controller, 50'.
      54-17-A0402 Wire, 22 gauge, 4 conductor,
      twisted pair, shielded with
      drain, used to connect toxic
      remote detectors with
      ZoneGuard controller, 50'.
      54-17-A0403 Wire, 18 gauge, 4 conductor,
      twisted pair, shielded with
      drain, used to connect combustible
      remote detectors with
      ZoneGuard controller, 50'.
      54-17-A0310 ZoneGuard airline adapter
      (10-200 psig) with Hanson
      fitting.
      35-0136 Calibration adapter for
      ZoneGuard and Gas Chek
      (Oxygen/standard toxic
      sensors).
      54-17-A0304 Calibration adapter for
      ZoneGuard and Gas Chek
      (LEL sensors).
      10-302 Calibration adapter for
      ZoneGuard and Gas Chek
      (Reactive gas sensors – Cl2).
      54-49-01 CO Sensor  
      54-49-90 O2 Sensor  
      54-9033 Calibration/Test Gas, CO 50 ppm, 103 liters (requires 12-023
      regulator).
      12-023 Regulator for 54-9033.
      54-9036 Calibration/Test Gas, \CO 50 ppm, 34 liters (requires 12-022
      regulator).
      12-022 Regula tor for 54-9036.
      54-51-001 Calibration Kit (includes 54-9033 CO calibration/test gas,
      12-023 regulator and foam lined plastic carrying case).
      54-51-002 Value Calibration Kit (includes 54-9036 CO calibration/test gas,
      12-022 regulator and foam lined plastic carrying case).
      54-51-003 Filter Kit (includes Pre-filter, coalescing filter, charcoal filter,
      and O-rings).
      54-50-002 A= 1 CO
      3 CO and O2
      B= 0 No Options
      1 LED Strobe Light
      2 Locking Stabilizer Legs
      3 Both
      C= 0 No Option
      1 Low Pressure Alarm
      D=N Rechargeable
      A Alkaline  
      E =H Hansen outlet fitting
      S Schraeder outlet fitting
      54-50-331NH Travel Panel 50MP with CO/O2 sensors,LED
      Strobe Light, Locking Stabilize Legs, Low Pressure
      Alarm, Rechargeable battery, and Hansen outlet
      fittings.
      54-50-100NH Hansen Outlet Fittings.
      54-50-100NS Schraeder Outlet Fittings.
      54-05-A0403 Plastic Standard barb fitting.
      54-05-A0405 Stainless Steel Standard barb fitting.
      54-36-03 Plastic Male quick disconnect (QD).
      54-36-04 Stainless Steel Male quick disconnect (QD).
      54-36-05 Plastic Threaded for quick disconnect. Intended as replacement
      where existing QD is reused.
      54-36-06 Stainless Steel Threaded for quick disconnect. Intended as replacement
      where existing QD is reused.
      10-270 Standard probe handle (upper)
      61-047 Hydrophobic filter
      10-268 Filter cup
      10-267 Probe handle (lower)
      10-269 Hex-nut compression fitting
      17-063 O-ring
      05-1153 Male quick disconnect for threaded probe
      10-423 Threaded probe handle (upper)
      61-046 Particulate filter
      17-033 O-ring
      56-173 Compression sleeve
      56-439 Interchangeable probe tube, Plastic
      56-919 Interchangeable probe tube, Steel
      54-05-K0401 Filter replacement kit.
      10 Particulate (61-046).
      3 Hydrophobic (61-047) filters.
      54-05-K0403 Economy filter replacement kit.
      30 Particulate (61-046).
      10 Hydrophobic (61-047) filters.
      54-05-K0402 Economy filter replacement
      pack. 10 Particulate (61-046)
      filters.
      54-05-K0405 Bulk filter replacement pack.
      100 Particulate (61-046) filters.
      54-05-K0404 Bulk filter replacement pack.
      25 Hydrophobic (61-047) filters.
      54-05-K0406 100 Hydrophobic filters.
      54-05-K0407 500 Hydrophobic filters.
      53-001 Polyurethane (fuel resistant)
      tubing 5/16" OD, 3/16" ID.
      35-0344 Tubing kit for reactive gas
      detection (Cl2). Includes 10  of
      tubing plus adapters.
      Internal Filters
      for Motorized Pumps
      PART NO. DESCRIPTION
      54-05-K0101 Internal filter kit for PhD
      pumps. 10 particulate filters.
      54-36-17 Internal filter kit for
      Cannonball3. 10 particulate,
      5 hydrophobic filters.
      35-0408 In-line cartridge filter for
      Cannonball3. 1 particulate
      filter.
      54-20-1117-32 Low & High Pressure
      with Middle Stage
      Transducer, including
      Enhanced Precision
      (EP) Transducer and
      32-Bit PosiChek3
      software
      54-20-1117-32-L PosiChek3 (EP) with
      laptop computer
      package
      54-20-1117-32-D PosiChek3 (EP)
      with desktop
      computer package
      54-20-2117-32 Low & High Pressure
      with Middle Stage
      Transducer, including
      Enhanced Precision
      (EP) Transducer,
      Sound Detection
      System (SDS) and
      32-Bit PosiChek3
      software
      54-20-1117-32-L PosiChek3 (EP & SDS)
      with laptop computer
      package
      Upgrade your existing PosiChek3
      PART NO. DESCRIPTION
      54-21-A12 Enhanced Precision
      (EP) Transducer
      Upgrade
      54-21-A13 Sound Detection
      System (SDS) Upgrade
      (Must have EP)
      54-21-A14 EP and SDS Upgrade
    在线询盘/留言
  • 0571-87774297