UPS output power rating (0,9 p.f.)
|
kVA
|
225
|
275
|
450
|
550
|
675
|
825
|
900
|
1100
|
kW
|
204
|
250
|
408
|
500
|
612
|
750
|
816
|
1000
|
General
|
Efficiency in double conversion mode (full load)
|
> 94% (without transformer)
|
Efficiency in double conversion mode (half load)
|
> 93% (without transformer)
|
VMMS (double conversion)
|
significantly increased efficiency at low loads
|
Efficiency in Energy Saver System (ESS)
|
up to 99%
|
Distributed paralleling with Hot Sync technology
|
5 + 1
|
Field upgradeable
|
yes
|
Inverter/rectifier topology
|
transformer-free IGBT with PWM
|
Audible noise
|
< 76 dB; < 81 dB (825 and 1100 kVA)
|
Colour
|
RAL 7035
|
Input
|
Nominal voltage rating (configurable)
|
220/380, 230/400, 240/415 V 50/60 Hz
|
With external transformer
|
e.g. 230, 440, 480, 690 V
|
Input voltage range
|
+15% / -15%, +10% / -10% for bypass
|
Input frequency range
|
45-65 Hz
|
Input power factor
|
0,99
|
Input ITHD
|
< 3-5% on nominal load, depending on the utility UTHD
|
Soft start capability
|
Yes
|
Internal backfeed protection
|
Yes
|
Output
|
Nominal voltage rating (configurable)
|
220/380, 230/400, 240/415 V 50/60 Hz
|
With external transformer
|
e.g. 230, 440, 480, 690 V
|
Output UTHD
|
<3% (100% linear load); <5% (reference non linear load)
|
Output power factor
|
0,9 (e.g. 250 kW at 275 kVA)
|
Permitted load power factor
|
0,7 lagging - 0,8 leading
|
Overload on inverter
|
10 min 100-110%; 30 sec 110-125%; 10 sec 125-150%; 300 ms >150%
|
Overload when bypass available
|
Continuous <115%, 20 ms 1000% Note! Bypass fuses may limit the overload capability
|
Battery
|
Type
|
VRLA, AGM, Gel, Wet Cell (NiCd batteries on request)
|
Charging method
|
ABM technology or Float
|
Temperature compensation
|
Optional
|
Battery nominal voltage (lead-acid)
|
480 V (40 x 12 V, 240 cells)
|
Charging current / Model
Default A
Max* A
|
275
38
83
|
550
76
166
|
825
114
249
|
1100
152
332
|
*Limited by maximum UPS input current rating
|
Dimension and weights*
|
225 kVA, 275 kVA
|
1364 x 1152 x 2158 mm (wxdxh)
|
1000 kg
|
225 kVA redundant,
275 kVA redundant
|
1904 x 1152 x 2158 mm
|
1600 kg
|
450, 500, 550 kVA
|
1904 x 1152 x 2158 mm
|
1600 kg
|
450, 550 kVA redundant
|
2644 x 1152 x 2158 mm
|
2400 kg
|
675, 825 kVA
|
3724 x 1152 x 2158 mm
|
2920 kg
|
675, 825 kVA + 1 redundant
|
4464 x 1152 x 2158 mm
|
3570 kg
|
1100 kVA
|
4464 x 1152 x 2158 mm
|
3570 kg
|
Accessories
|
|
External battery cabinets with long-life batteries, NiCd batteries on request, X-Slot connectivity (Web/SNMP, ModBus/Jbus, Relay, Hot Sync, ViewUPS-X remote display), integrated manual bypass for 225-550 kVA
|
Communications
|
X-Slot
|
4 communication bays
|
Serial ports
|
1 available
|
Relay inputs/outputs
|
5/1 programmable
|
Compliance with standards
|
Classification survey report
|
On request
|