For Sensor Relay Connector
Ratings and Specifications
*The operating temperature range is restricted by the maximum operating temperature of the cable.
Wiring Procedure
Wire Preparation
Use the strip gauge on the
front panel and strip 7 to 8 mm
of the insulation. If you use
stranded wires, twist them
several times.
Connection Procedure
1. Press a flat-blade
screwdriver into the
operation hole until
the operation lever
locks into place.
2. Insert the wire all the way into the wire insertion hole. Confirm that
the insulation on the wire also enters the wire insertion hole and
that the end of the wire has passed through the connection
section.
3. Insert a flat-blade screwdriver
into the release hole and
gently reset the lever. You
should hear the operation
lever reset.
4. Finally, check the following items.
• Make sure the operation lever has been
reset.
• Check the items given in step 2 again.
(Pull lightly on the wire to see if it is held
firmly in place.)
Disconnection Procedure
1. Press in the operation level, confirm
that the operation lever is locked into
place, and then pull out the wire.
2. After you remove the wire, always
reset the operation lever. However, if
you are going to connect another wire
to the same terminal, you do not need
to reset the operation lever and can
immediately connect the other wire.
Appearance Number of poles Model
4 XN2A-1470
|