品牌:富士 | 产地:日本 | 价格:460人民币/只 | 规格: | 简要说明: PXW5,PXW7,PXW9型号已淘汰,对应的替代产品为PXR5,PXR7,PXR9。 | | | | 详细介绍:
PXR5/PXR7/PXR9 系列选型说明 |
数
字
位 |
规 格 |
代 号 |
4 |
5 |
6 |
7 |
8 |
- |
9 |
10 |
11 |
12 |
13 |
4 |
面板尺寸W×H |
|
|
|
|
|
|
|
|
|
|
|
48 × 96 |
5 |
|
|
|
|
|
|
|
|
|
|
72 × 72 |
7 |
|
|
|
|
|
|
|
|
|
|
96 × 96 |
9 |
|
|
|
|
|
|
|
|
|
|
5 |
输入信号 |
|
|
|
|
|
|
|
|
|
|
|
热电偶( C ) |
|
T |
|
|
|
|
|
|
|
|
|
热电偶( F ) |
|
R |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( C ) |
|
N |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( F ) |
|
S |
|
|
|
|
|
|
|
|
|
1-5V DC |
|
A |
|
|
|
|
|
|
|
|
|
4-20mA DC 注1 |
|
B |
|
|
|
|
|
|
|
|
|
6 |
控制输出1 |
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出 |
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
C |
|
|
|
|
|
|
|
|
4-20mA DC输出 |
|
|
E |
|
|
|
|
|
|
|
|
7 |
控制输出2 |
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
Y |
|
|
|
|
|
|
|
继电器接点输出 |
|
|
|
A |
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
|
C |
|
|
|
|
|
|
|
4-20mA DC |
|
|
|
E |
|
|
|
|
|
|
|
再传输输出( 4~20mA DC ) |
|
|
|
R |
|
|
|
|
|
|
|
8 |
版本号 |
|
|
|
|
1 |
— |
|
|
|
|
|
9 |
附加功能1 |
|
|
|
|
|
|
|
|
|
|
|
无报警 |
|
|
|
|
|
|
0 |
|
|
|
|
1个报警 |
|
|
|
|
|
|
8 |
|
|
|
|
加热器断路报警 注2 |
|
|
|
|
|
|
2 |
|
|
|
|
1个报警 + 加热器断路报警 注2 |
|
|
|
|
|
|
3 |
|
|
|
|
8段斜坡 / 保温程序 |
|
|
|
|
|
|
4 |
|
|
|
|
1个报警 +8 段斜坡 / 保温程序 |
|
|
|
|
|
|
5 |
|
|
|
|
加热器断路报警 +8 段斜坡 / 保温程序 注2 |
|
|
|
|
|
|
6 |
|
|
|
|
1个报警 + 加热器断路报警 +8 段斜坡 / 保温程序 注2 |
|
|
|
|
|
|
7 |
|
|
|
|
两个报警 |
|
|
|
|
|
|
F |
|
|
|
|
两个报警 +8 段斜坡 / 保温 |
|
|
|
|
|
|
G |
|
|
|
|
两个报警 + 加热器断路报警 +8 段斜坡 / 保温程序 注2 |
|
|
|
|
|
|
H |
|
|
|
|
3个报警 |
|
|
|
|
|
|
M |
|
|
|
|
遥控设定 注2 |
|
|
|
|
|
|
D |
|
|
|
|
遥控设定 +2 个报警 注2 |
|
|
|
|
|
|
P |
|
|
|
|
10 |
操作说明书电源电压 |
|
|
|
|
|
|
|
|
|
|
|
无 100~240VAC |
|
|
|
|
|
|
|
N |
|
|
|
日文 100~240VAC |
|
|
|
|
|
|
|
Y |
|
|
|
英文 100~240VAC |
|
|
|
|
|
|
|
V |
|
|
|
无 24VAC/24DC |
|
|
|
|
|
|
|
C |
|
|
|
日文 24VAC/24DC |
|
|
|
|
|
|
|
A |
|
|
|
英文 24VAC/24DC |
|
|
|
|
|
|
|
B |
|
|
|
11
12
13 |
附加功能2 |
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
|
|
|
|
|
0 |
0 |
0 |
RS485( Modbus )通讯 |
|
|
|
|
|
|
|
|
M |
0 |
0 |
RS485( Z-ASC11 )通讯 |
|
|
|
|
|
|
|
|
N |
0 |
0 |
1点数字输入 |
|
|
|
|
|
|
|
|
S |
0 |
0 |
2点数字输入 注2 |
|
|
|
|
|
|
|
|
T |
0 |
0 |
RS485( Modbus )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
V |
0 |
0 |
RS485( Z-ASC11 )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
W |
0 |
0 |
注1:输出&, amp;, lt;, STRONG>4-20mA不能与加热器断路报警一起选 (即选项9中的2、3、6、7、H) |
注2:不能与RS485+1点数字输入一起选(即选项11、12、13中的V00) |
注3:若选择2点数字输入,输出2或加热器断路报警不能选 |
PXR4系列
|
PXV4 已淘汰,由PXR4替代
PXR4 系列选型说明 |
数
字
位 |
规 格 |
代 号 |
4 |
5 |
6 |
7 |
8 |
- |
9 |
10 |
11 |
12 |
13 |
4 |
面板尺寸W×H |
|
|
|
|
|
|
|
|
|
|
|
48 × 48 |
4 |
|
|
|
|
|
|
|
|
|
|
5 |
输入信号 |
|
|
|
|
|
|
|
|
|
|
|
热电偶( C ) |
|
T |
|
|
|
|
|
|
|
|
|
热电偶( F ) |
|
R |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( C ) |
|
N |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( F ) |
|
S |
|
|
|
|
|
|
|
|
|
1-5V DC |
|
A |
|
|
|
|
|
|
|
|
|
4-20mA DC |
|
B |
|
|
|
|
|
|
|
|
|
6 |
控制输出1 |
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出 |
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
C |
|
|
|
|
|
|
|
|
4-20mA DC输出 注1 |
|
|
E |
|
|
|
|
|
|
|
|
7 |
控制输出2 |
|
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
Y |
|
|
|
|
|
|
|
|
继电器接点输出 注2 |
|
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
|
C |
|
|
|
|
|
|
|
|
4-20mA DC |
|
|
|
E |
|
|
|
|
|
|
|
|
再传输出(4-20mA DC ) |
|
|
|
R |
|
|
|
|
|
|
|
8 |
版本号 |
|
|
|
|
&l, t;, DIV align=center>—
|
|
|
|
|
|
9 |
附加功能1 |
|
|
|
|
|
|
|
|
|
|
|
无报警 |
|
|
|
|
|
|
0 |
|
|
|
|
1个报警 |
|
|
|
|
|
|
1 |
|
|
|
|
加热器断路报警 注3 |
|
|
|
|
|
|
2 |
|
|
|
|
1个报警 + 加热器断路报 注3 |
|
|
|
|
|
|
3 |
|
|
|
|
8段斜坡 / 保温程序 |
|
|
|
|
|
|
4 |
|
|
|
|
1个报警 +8 段斜坡 / 保温程序 |
|
|
|
|
|
|
5 |
|
|
|
|
加热器断路报警 +8 段斜坡 / 保温程序注3 |
|
|
|
|
|
|
6 |
|
|
|
|
1个报警 + 加热器断路报警 +8 段斜坡 / 保温程序 注3 |
|
|
|
|
|
|
7 |
|
|
|
|
两个报警 |
|
|
|
|
|
|
F |
|
|
|
|
两个报警 +8 段斜坡 / 保温 |
|
|
|
|
|
|
G |
|
|
|
|
两个报警 + 加热器断路报警 +8 段斜坡 / 保温程序 注3 |
|
|
|
|
|
|
H |
|
|
|
|
3个报警 |
|
|
|
|
|
|
M |
|
|
|
|
遥控设定 注3 |
|
|
|
|
|
|
D |
|
|
|
|
遥控设定 +2 个报警 注3 |
|
|
|
|
|
|
P |
|
|
|
|
10 |
操作说明书电源电压 |
|
|
|
|
|
|
|
|
|
|
|
无 100~240VAC |
|
|
|
|
|
|
|
N |
|
|
|
日文 100~240VAC |
|
|
|
|
|
|
|
Y |
|
|
|
英文 100~240VAC |
|
|
|
|
|
|
|
V |
|
|
|
无 24VAC/24DC |
|
|
|
|
|
|
|
C |
|
|
|
日文 24VAC/24DC |
|
|
|
|
|
|
|
A |
|
|
|
英文 24VAC/24DC |
|
|
|
|
|
|
|
B |
|
|
|
11
12
13 |
附加功能2 |
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
|
|
|
|
|
0 |
0 |
0 |
RS485( Modbus )通讯 |
|
|
|
|
|
|
|
|
M |
0 |
0 |
RS485( Z-ASC11 )通讯 |
|
|
|
|
|
|
|
|
N |
0 |
0 |
1点数字输入 |
|
|
|
|
|
|
|
|
S |
0 |
0 |
2点数字输入 注4 |
|
|
|
|
|
|
|
|
T |
0 |
0 |
RS485( Modbus )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
V |
0 |
0 |
RS485( Z-ASC11 )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
W |
0 |
0 | ,
注1:输出4-20mA 不能与加热器断路报警一起选(即选项9中的2、3、6、7) |
注2:不能和1个报警+加热器断路报警或两个报警一起选 (即选项9中的3、7、F、G、H) |
注3:不能与RS485+1点数字输入一起选(即选项11、12、13中的V00) |
注4:若选择2点数字输入,输出2或加热器断路报警不能选 |
|
PXV3 已淘汰,由PXR3替代
PXR3 系列选型说明 |
数
字
位 |
规 格 |
代 号 |
4 |
5 |
6 |
7 |
8 |
- |
9 |
10 |
11 |
12 |
13 |
4 |
面板尺寸W×H |
|
|
|
|
|
|
|
|
|
|
|
24 × 48 |
3 |
|
|
|
|
|
|
|
|
|
|
5 |
输入信号 |
|
|
|
|
|
|
|
|
|
|
|
热电偶( C ) |
|
T |
|
|
|
|
|
|
|
|
|
热电偶( F ) |
|
R |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( C ) |
|
N |
|
|
|
|
|
|
|
|
|
RTD/Pt100欧姆( F ) |
|
S |
|
|
|
|
|
|
|
|
|
1-5V DC |
|
A |
|
|
|
|
|
|
|
|
|
4-20mA DC |
|
B |
|
|
|
|
|
|
|
|
|
6 |
控制输出1 |
|
|
|
|
|
|
|
|
|
|
|
继电器接点输出 |
|
|
A |
|
|
|
|
|
|
|
|
SSR/SSC驱动输出 |
|
|
C |
|
|
|
|
|
|
|
|
4-20mA DC输出 |
|
|
E |
|
|
|
|
|
|
|
|
7 |
控制输出2 |
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
Y |
|
|
|
|
|
|
|
继电器接点输出 注1 |
|
|
|
A |
|
|
|
|
|
|
|
SSR/SSC驱动输出 注1 |
|
|
|
C |
|
|
|
|
|
|
|
4-20mA DC 注1 |
|
|
|
E |
|
|
|
|
|
|
|
8 |
版本号 |
|
|
|
|
1 |
— |
|
|
|
|
|
9 |
附加功能1 |
|
|
|
|
|
|
|
|
|
|
|
无报警 |
|
|
|
|
|
|
0 |
|
|
|
|
1个报警 |
|
|
|
|
|
|
1 |
|
|
|
|
8段斜坡 / 保温程序 |
|
|
|
|
|
|
4 |
|
|
|
|
1个报警 +8 段斜坡 / 保温程序 |
|
|
|
|
|
|
5 |
|
|
|
|
两个报警 注2 |
|
|
|
|
|
|
F |
|
|
|
|
两个报警 +8 段斜坡 / 保温 注2 |
|
|
|
|
|
|
G |
|
|
|
|
10 |
操作说明书电源电压 |
|
|
|
|
|
|
|
|
|
|
|
无 100~240VAC |
|
|
|
|
|
|
|
N |
|
|
|
日文 100~240VAC |
|
|
|
|
|
|
|
Y |
|
|
|
英文 100~240VAC |
|
|
|
|
|
|
|
V |
|
|
|
无 24VAC/24DC |
|
|
|
|
|
|
|
C |
|
|
|
日文 24VAC/24DC |
|
|
|
|
|
|
|
A |
|
|
|
英文 24VAC/24DC |
|
|
|
|
|
|
|
B |
|
|
|
11
12
13 |
附加功能2 |
|
|
|
|
|
|
|
|
|
|
|
无 |
|
|
|
|
|
|
|
|
0 |
0 |
0 |
RS485( Modbus )通讯 |
|
|
|
|
|
|
|
|
M |
0 |
0 |
RS485( Z-ASC11 )通讯 |
|
|
|
|
|
|
|
|
N |
0 |
0 |
再传输出+1点数字输入 注3 |
|
|
|
|
|
|
|
|
Q |
0 |
0 |
再传输出 注3 |
|
|
|
|
|
|
|
|
R |
0 |
0 |
2点数字输入 |
|
|
|
|
|
|
|
|
T |
0 |
0 |
RS485( Modbus )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
V |
0 |
0 |
RS485( Z-ASC11 )通讯 +1 点数字输入 |
|
|
|
|
|
|
|
|
W |
0 |
0 |
注1:两个过程报警(即选项9中的F和G)不能一起选 |
注2:控制输出2(即选项7中的A、C、E)不能一起选 |
注3:控制输出2,两个报警和24V电源不能一起选 (即选项7中的A、C、E,选项9中的F和G,选项10中的A、B、C) |
产品简介: 双排显示PV、SP等数据; 12种热电偶信号、3种热电阻信号、5种线形信号输入; 继电器输出、电压、电流信号输出; 带手/自动模式,切换便利; 多种辅助输出功能; 多种控制算法输出: ON/OFF、PID、双重(冷热区)输出、马达阀门控制、单相/三相可控硅控制、 三路(可选)报警输出,17种报警类型; 8段设定点程序; 满量程0.5%精度,EEROM非易失性内存,确保数据在掉电情况下不会丢失; 85-256Vac/50(60)HZ供电工作。 |
产品用途: 用于各种温度控制。
|
规格型号:
PXR5 (48 × 96mm)
PXR7 (72 × 72mm)
PXR9 (96 × 96mm)
PXR4 (48 × 48mm)
PXR3 (24 × 48mm) |
其它说明:
PXW5/7/9 已淘汰,由PXR5/7/9替代 | |
|
|
|
|